TROUBLE SHOOTING
Condition
Analysis
Looking for material for a long time,
or Venturi Loader doesn’t run.
The main switch and control switch doesn’t open
or the above two aren’t connected properly.
The proximity sensor isn’t connected properly.
The signal wire is loose or broken.
Loss of air pressure.
The hopper is full,but the Venturi
Loader still runs.
The proximity sensor doesn't release.
The signal wire is short circuited.
After several times of loading the
material hopper is still empty.
The incoming material storage tank is empty.
The pipe has an air leak.
The filter is blocked.
The air pressure is too low.
ELECTRIC DIAGRAM
Symbol
Component Name
Model
S1
Rocker Switch, Power
FXPS156
S2
Proximity Switch
K15082
Y1
Magnetic Valve
LVSN125FX
F1
Fuse, 1A
AGC-1
4/19