SAFETY PRECAUTIONS

Storage of the machine.

STORAGE:

1)

LV-FX Series should be stored indoors with temperature kept from 41°F to 104°F and humidity
below 80% if possible.

2)

Disconnect all power and turn off main switch and control switch.

3)

Keep the whole machine, especially the electrical components away from water.

4)

Plastic film should be used to protect the machine from dust and moisture when not in use.

WORKING ENVIRONMENT:

1)

The machine should be operated indoors in a dry environment with max. temperature 113°F and
humidity no more than 80%.

2)

A clearance of at least 3 feet surrounding the equipment is required during operation. Keep this
equipment at least 6 feet away from flammable sources.

3)

Avoid vibration and magnetic disturbance at the operation area.

DO NOT USE THE MACHINE:

1)

If it is has a damaged power cord.

2)

On a wet floor or when it is exposed to moisture, to avoid electrical shock.

3)

If it has been dropped or damaged until it is checked or fixed by a qualified serviceman.

FIRE HAZARD:

1)

In case of fire, CO2 dry powder fire extinguisher should be applied.

2)

Attention: No need for regular inspection because all of the electrical parts in the control unit are
fixed tightly!

INSTALLATION

The Venturi loader can be installed directly on the plastic material hopper. CAUTION: Be sure to fasten
the loader in place as they are top heavy when conveying material plus the extra weight of the vacuum
hose. Connect the venturi poly tubing 10mm x 13' to the suction probe. Then connect the other side to
the “OUT” side of the control box. Expose 1” of the grounding wire on the 1-1/4” I.D. material hose on
each end. Fasten one end to the suction probe and the other end to the inlet of the venturi body with the
clamps that were included. 

Failure to connect the ground wire can cause excessive static buildup

and can result in possible static shock to personnel or damage the unit control  circuit board.

Connect a 10mm tube air supply to the “IN” side of the control box. The air regulator is preset at the
factory. To reset the air pressure you must lift the pressure control knob reset the pressure and lock the
knob by pushing it down until it clicks. DO NOT reset air pressure with power on!! For dual feed model
follow procedures as listed above except you have 2 hoses and suction probes plus 2 control boxes.
One control box is the master (No. 1 supplies power) and the second is the slave (No. 2). Plug the slave
box into the master to energize the slave box. Both control boxes have power switches so the slave box
(regrind) can be shut down if necessary.

6

Summary of Contents for LV-FX Series

Page 1: ...433 6385 800 258 8877 Fax 702 433 6388 PPE W E S T PPE S O U T H 11218 Challenger Avenue Odessa Florida 33556 727 834 8888 800 282 6783 Fax 727 834 8873 Toll Free USA Canada Mexico 800 362 0706 PLASTI...

Page 2: ...or death This signal word is limited to the most extreme situations Always follow the warnings or instructions that accompany the danger label such as High Voltage Acid Hot Surface etc etc etc See La...

Page 3: ...ials plus easy to clean polished surfaces 3 Filtered exhaust air does not pollute environment 4 Silent operation uses high pressure air to convey materials no motor noise 5 Proximity switch sensor mou...

Page 4: ...Hopper Stainless Steel 10A Air Supply in 5 Pressure Gauge 11 Compressed air filter regulator 1 4 NPT 6 Air filter 12 Solenoid Air 7 Clamping Knob Filter 13 Control Box 8 Sensor Proximity Switch You m...

Page 5: ...pellets SAFETY PRECAUTIONS Transportation of the machine TRANSPORTATION 1 LV FX series are packed in a cardboard box 2 Do not invert the machine and avoid collision with other objects during transport...

Page 6: ...until it is checked or fixed by a qualified serviceman FIRE HAZARD 1 In case of fire CO2 dry powder fire extinguisher should be applied 2 Attention No need for regular inspection because all of the e...

Page 7: ...rial types sizes velocity ambient temperatures dryness etc etc can or will generate static electricity seeking a release to ground If you suspect this condition we strongly suggest you add an addition...

Page 8: ...king for material for a long time or Venturi Loader doesn t run The main switch and control switch doesn t open or the above two aren t connected properly The proximity sensor isn t connected properly...

Reviews:

Related manuals for LV-FX Series