PPA DZ BRUTALLE 2.0T JetFlex Technical Manual Download Page 6

10

11

2nd Step:

 The dimensions of the base must be appropriate for the dimensions of 

the operator. The concrete base should be at a distance of approximately 20 mm 

from the face of the gate leaf.

3rd Step: 

Once the conditions are attend, fully open the gate and position the 

operator close to the face of the gate leaf, obeying the 50 mm measurement 

between the leaf end and the concrete base.

4th Step:

 Pre-align the operator to the gate, positioning the rack over the gear and 

leaning the set against the gate. Then mark the fixing holes in the floor or concrete 

base.

5th Step:

 Drill holes for fixing, positioning the operator aligned with the gate. 

Before tightening the 1/2” x 4” parabolt anchors, move the gate, checking that 

it does not touch the operator during its journey. If this happens, back off the 

operator.

20 mm

VISTA LATERAL

FOLHA DO PORTÃO

BASE DE CONCRETO

50mm

MARCAR OS FUROS  

DE FIXAÇÃO NO PISO

DE FIXAÇÃO NO PISO

MARCAR OS FUROS 

FUROS DE FIXAÇÃO

DO AUTOMATIZADOR

FUROS DE FIXAÇÃO

DO AUTOMATIZADOR

PARABOLT

PARABOLT

 GATE LEAF

SIDE VIEW

MARK THE FLOOR

FIXING HOLES

AUTOMATIZER 

FIXING HOLES

AUTOMATIZER 

FIXING HOLES

MARK THE FLOOR 

FIXING HOLES

 CONCRETE BASE

Summary of Contents for DZ BRUTALLE 2.0T JetFlex

Page 1: ...ction manual DZ BRUTALLE Technical Manual P30452 04 2022 Rev 1 Made by Motoppar Ind stria e Com rcio de Automatizadores Ltda Av Dr Labieno da Costa Machado 3526 Distrito Industrial Gar a SP CEP 17406...

Page 2: ...ICAL CHARACTERISTICS 5 TOOLS REQUIRED FOR INSTALLATION 6 ELECTRICAL INSTALLATION 6 CARE WITH THE ELECTRICAL INSTALLATION 7 GATE CARE BEFORE AUTOMATION 8 INSTALLATION AND FIXING OF THE OPERATOR 9 ANALO...

Page 3: ...mandatory when installing the operator TECHNICAL CHARACTERISTICS DZ BRUTALLE 3 0T Z12 Z17 TYPE OF OPERATOR Sliding MODEL JetFlex RATED VOLTAGE 127V 220V NOMINAL FREQUENCY 60 Hz RATED POWER 180W 150W E...

Page 4: ...be a flexible cable 3 x 0 75 mm 500 V according to the NBR standard NM 247 5 The power conductor of a product for external use must be a flexible cable 3 x 0 75 mm 500 V as per the standard IEC 60245...

Page 5: ...that uses a straight section Picture A angle presents greater friction and consequently greater wear The circular section Picture B allows for better gate displacement and less friction for the opera...

Page 6: ...ng the set against the gate Then mark the fixing holes in the floor or concrete base 5th Step Drill holes for fixing positioning the operator aligned with the gate Before tightening the 1 2 x 4 parabo...

Page 7: ...rew every 300 or 400 mm 8th Step If the gate leaf is warped provide wedges to ensure rack alignment There are cases where the rack will need to extend the length of the sheet In this case provide a Fr...

Page 8: ...the operator s REED This magnet will act as the opening limit switch 3rd Step Start the engine and observe if the REED s are shutting down correctly If necessary invert the board connector Once the m...

Page 9: ...ace fuse with same specification C Make sure there is no object blocking the gate operation D Replace the course end system analog and or digital Engine blocked A Inverted motor connection B Locked ga...

Reviews: