GATE CARE BEFORE AUTOMATION

Before adapting the machine to the gate, check the slip, following the instructions 

below:

1st Step:

 Before installing the operator, check that the gate is in good mechanical 

condition, that is, opening and closing properly. Manually open the gate and note 

the effort required. This effort must be minimal along the entire length of the 

course.

2nd Step:

 Close the gate manually and check if the effort exerted was equal to the 

previous operation.

The gate must have a strong structure and, as much as possible, non-deformable. 

The pulleys must have a diameter consistent with the dimensions of the gate, be 

in perfect rolling condition and mounted in such a way that the leaf the gate has 

stability throughout its displacement. We recommend pulleys with a minimum 

diameter of 120 mm.

The pictures below represent the two types of rails and pulleys used. The system 

that uses a straight section (Picture A - angle) presents greater friction and 

consequently greater wear. The circular section (Picture B) allows for better gate 

displacement and less friction for the operator.

3rd Step:

 Check that the gate leaf does not get stuck in the opening and closing 

movement. The gate’s sliding rail must be perfectly straight, level, periodically free 

of any element or dirt that makes it difficult for the pulleys to slide along their 

entire length, as shown in the figure below.

INSTALLATION AND FIXING OF THE 
OPERATOR

Before installing the operator, remove all unnecessary cables and disable any 

equipment or system connected to the electrical network.

EQUIPMENT DIMENSIONS

The perfect functioning of this equipment depends on the instructions contained 

in this manual. To secure the equipment, proceed as follows:

1st Step:

 Check that the floor is firm enough so that the equipment can be screwed 

so that it is level. If you do not comply with the requirement, provide a concrete 

base, following the guidelines below:

275 mm

450 mm

400 mm

448

mm

245 mm

PICTURE A

PICTURE B

Summary of Contents for DZ BRUTALLE 2.0T JetFlex

Page 1: ...ction manual DZ BRUTALLE Technical Manual P30452 04 2022 Rev 1 Made by Motoppar Ind stria e Com rcio de Automatizadores Ltda Av Dr Labieno da Costa Machado 3526 Distrito Industrial Gar a SP CEP 17406...

Page 2: ...ICAL CHARACTERISTICS 5 TOOLS REQUIRED FOR INSTALLATION 6 ELECTRICAL INSTALLATION 6 CARE WITH THE ELECTRICAL INSTALLATION 7 GATE CARE BEFORE AUTOMATION 8 INSTALLATION AND FIXING OF THE OPERATOR 9 ANALO...

Page 3: ...mandatory when installing the operator TECHNICAL CHARACTERISTICS DZ BRUTALLE 3 0T Z12 Z17 TYPE OF OPERATOR Sliding MODEL JetFlex RATED VOLTAGE 127V 220V NOMINAL FREQUENCY 60 Hz RATED POWER 180W 150W E...

Page 4: ...be a flexible cable 3 x 0 75 mm 500 V according to the NBR standard NM 247 5 The power conductor of a product for external use must be a flexible cable 3 x 0 75 mm 500 V as per the standard IEC 60245...

Page 5: ...that uses a straight section Picture A angle presents greater friction and consequently greater wear The circular section Picture B allows for better gate displacement and less friction for the opera...

Page 6: ...ng the set against the gate Then mark the fixing holes in the floor or concrete base 5th Step Drill holes for fixing positioning the operator aligned with the gate Before tightening the 1 2 x 4 parabo...

Page 7: ...rew every 300 or 400 mm 8th Step If the gate leaf is warped provide wedges to ensure rack alignment There are cases where the rack will need to extend the length of the sheet In this case provide a Fr...

Page 8: ...the operator s REED This magnet will act as the opening limit switch 3rd Step Start the engine and observe if the REED s are shutting down correctly If necessary invert the board connector Once the m...

Page 9: ...ace fuse with same specification C Make sure there is no object blocking the gate operation D Replace the course end system analog and or digital Engine blocked A Inverted motor connection B Locked ga...

Reviews: