background image

6

7

- The cable for the fixed wiring must comply with NBR NM 247-3;

- The power conductor of a product for internal use must be a 

flexible cable 3 x 0.75 mm²; 500 V, according to the norm NBR NM 

247-5;

- The power conductor of a product for external use must be a 

flexible cable 3 x 0.75 mm²; 500 V, according to IEC 60245-57.

It is mandatory that the 

ground terminal is connected 

to the ground.

IMPORTANT

The device must be powered by a residual current (DR) device, 

with a rated residual current exceeding 30 mA.

PRECAUTIONS WITH THE GATE BEFORE 
INSTALLATION

Before applying the automation to the gate, some procedures should be taken:

-Before installing the operator, check that the gate is in good mechanical condition, 

that is, opening and closing properly. Open the gate manually and observe the 

effort required. This effort must be minimal along the entire length of the path.- 

Check the balance of the gate leaf. Lift the leaf halfway up and see if it remains 

stationary. If the leaf remains stationary, the gate will be satisfactorily balanced. 

This equilibrium condition must occur for approximately 80% of the stroke, and 

imbalance near the extremes of the stroke end is admissible;

-Remove any equipment not necessary for the operation of the device, such as 

locks, ropes, chains, tools, among others.

-The unlocking (manual release) must be installed at a height of less than 1.8 m;

-In the case of push button installations (optional fixed control), install at a height 

of at least 1.5 m from the floor and in view of the door, further away from moving 

parts;

-Fix crush risk warning, available in the automation kit, in places visible or near the 

button (fixed control);

-Check the manual release system, fastened next to the actuation element of the 

unlocking;

-Move the door leaf manually (opening and closing) and observe the required 

effort. The leaf should rise and fall, throughout the course, with the minimum of 

effort;

-The gate shall have a sturdy and, as far as possible, non-deformable structure.

FIXATION AND INSTALLATION OF THE 
OPERATOR

Before installing the automation system, remove any unnecessary 

cables and disable any equipment or system connected to the elec-

trical grid.

Summary of Contents for BV POTENZA PREDIAL CUSTOM

Page 1: ...ion manual BV POTENZA PREDIAL Technical Manual P30705 05 2022 Rev 1 Made by Motoppar Ind stria e Com rcio de Automatizadores Ltda Av Dr Labieno da Costa Machado 3526 Distrito Industrial Gar a SP CEP 1...

Page 2: ...ith that required on the equipment iden tification label Do not connect the electrical grid until ins tallation maintenance is complete Always make electrical connections to the control unit with the...

Page 3: ...7 m min MANEUVERS 30 cycles h 50 cycles h 30 cycles h 50 cycles h DEGREE OF PROTECTION IPX4 IPX4 IPX4 IPX4 RAIL Aluminum Steel Aluminum Steel Aluminum Steel Aluminum Steel TEMPERATURE RANGE 5 C 50 C 5...

Page 4: ...s stationary the gate will be satisfactorily balanced This equilibrium condition must occur for approximately 80 of the stroke and imbalance near the extremes of the stroke end is admissible Remove an...

Page 5: ...af Step 2 Remove the top rail cover and install the securing brackets on the opposite side to the drive nut pin ARTICULATING ARM GATE LEAF HALF OF GATE LEAF GATE AXIS Step 3 Insert the closing stop wi...

Page 6: ...e center of the turning point of the drive lever and the center of the drive nut pin Step 10 Still with the gate closed adjust the closing stop so that the rubber of the gate cushion the drive nut in...

Page 7: ...art does not move A Power off B Open burned fuse C Locked gate D Defective limit switch A Make sure that the power supply is connected correctly B Replace fuse with the same specification C Make sure...

Reviews: