PZN Aquamatic Water Heater
Doc Ref M107 issue 1.3 Sep 2018.
• position the main switch to OFF.
• check that the water system drain valve is closed;
• open the upper manual bleed valve.
• start filling by slowly opening the water system filling
valve external to the heater unit;
• when water begins flowing out of the bleed valve
close the latter and continue filling until correct system
pressure is reached;
• repeat the procedure after the heater has been running
a few hours and periodically check pressure;
• check that there are no leaks.
WARNING: If there is a risk of sub-zero
temperatures mix some anti-freeze into the
water in manufacturer-recommended
quantities.
When the unit is delivered the directional louvres are
almost completely closed. The horizontal louvres must
be adjusted during installation so as to create an airflow
suitable for the room/area being heated. Such airflow
must not disturb the persons occupying such room/area.
The louvres can be individually adjusted manually.
Do not close the horizontal louvres
completely.
Adjust the flow directing fins by grabbing
them on the extremity.
Use suitable protective equipment.