8
Battery
Level
Monitor
Main Panel
Power
Control
Switch
Forward/
Reverse
Switch
Speed
Control
Key
Brush
Switch
Water
Switch
Vacuum
Switch
Recovery
Tank Full
Indicator
CAUTION:
This machine is designed to work in closed industrial environments on level floors or on
inclines no steeper than 2%. Do not use flammable chemicals and/or explosives with this machine.
Do not use or pick up flammable chemicals or liquids with this machine.
Brush:
The brush must be kept in working order; to remove a worn brush proceed as follows
Turn off the machine (key switch in 0 position) and lift the brush with the pedal M7 (page 7);
Unhook the brush by rotating it manually and dropping it onto the floor.
Replace the brush with the new one leaving it one the floor under the unit.
Turn on the machine again as described in the previous paragraph, put the speed potentiometer in
the zero position. Operate the lever M8 (page 9) to turn ON the brush motor.
Release the pedal M7 (page 7). If the brush isn’t hooked up immediately you have to make small side
movements with the unit until the brush is hooked up.
WARNING: the use of brushes and non original spare parts can be dangerous. IN ANY CASE
FOR YOUR SAFETY AFTER THE ROTATION OF THE BRUSH BE CAREFUL NOT TO COME IN
TOUCH WITH MOVING PARTS OR ROTATION.
The machine is supplied with a pad driver and a red pad.
Batteries
: Check the electrolyte level and top up with distilled water if drops below the level of
the battery elements. Keep the batteries clean and dry with anti-static cloths. Recharging must be
carried out with the cell plugs removed and the cover of the machine opened so as to allow the gases
generated to escape. In confined spaces these gases can be explosive, so recharging should be
done in a well ventilated area.