P
OWERWINCH
M
OTORIZED
F
OLDING
C
AMPER
W
INCH
9
T
ROUBLESHOOTING
G
UIDE
W
INCH
D
OES
N
OT
O
PERATE
A. Confirm power to winch
1. Check battery is fully charged
2. Confirm connections are for tight & clean.
3. Check if wires are worn or bare that may
cause shorts
Correct as required.
B. Check circuit breaker at battery
Bypass circuit breaker and test winch.
Does the winch run?
CAUTION
Do not operate the winch
without the circuit breaker. Removing the CB
from the circuit is
ONLY
for testing.
Y
ES
If winch runs, circuit
breaker is bad, replace.
N
O
Reconnect circuit breaker
and go to step C.
C
AMPER
T
OP OVER OR UNDER
E
XTENDS
A. Lower Limit Switch: If the motor continues
to run after the top is down; or, the motor
stops before the top is down.
The lower limit switch is set
incorrectly. Refer to "Setting the
Lower Limit Switch" on page 5.
B. Upper Limit Switch: If the motor continues
to run after the camper top is fully raised;
or, the top is not raised high enough
before the motor shuts off.
The upper limit switch is set
incorrectly. Refer to "Setting the
Upper Limit Switch" on page 6.
W
INCH
O
PERATES
O
PPOSITE THE
P
LATE
M
ARKINGS
A. Use the wiring diagram on page 8 to check
that the wiring is correct. Ensure that the red
wire with the circuit breaker is attached to the
positive (+) terminal of the battery
Correct as required.