Installation Instructions (Refer to figures 1-1 and 2-1)
The SPA 9321-30C is intended for installation in a Restricted Access Location.
The SPA 9321-30C amplifier module is designed for installation in a subrack that permits access
to the amplifier’s front panel for connection of DC power, RF, and monitor cables.
To install the amplifier proceed as follows:
1.
Install amplifier in the BTS rack and secure in place.
2.
Connect the amplifier front panel RF Out (Type-N) connector to the antenna cable.
3.
Connect the amplifier front panel RF In (Type-SMA) connector to the transceiver output(s).
4.
Connect the BTS 20-pin Data I/O cable to the amplifier. Refer to section 2-5.1.
W
ARNING
Turn off external DC power before connecting DC power cables. Verify that the
amplifier is terminated into a proper 50 Ohm load.
5.
Connect the DC power cable to the rack and amplifier. Refer to section 2-5.3.
6.
Check your work before applying DC voltage to the system. Make certain all connections
are tight and correct.
7.
Measure DC input voltage. DC input voltage should be -36 to –60 VDC. If the DC input volt-
age is above or below the limits, call and consult Powerwave before you turn on your ampli-
fier system.
8.
Refer to section 3 for initial turn-on and checkout procedures.
2-5
Amplifier Module Connectors
The amplifier has four connectors on the front of the module. These include a SCSI connector
which provides the data I/O connections, SMA female RF input, Type N female RF output, and
3-pin high current contact DC input connectors. Refer to figure 2-1. Each is fully described in the
paragraphs that follow.
Figure 2-1 SPA 9321-30C Front Panel View