background image

SPA 9321-30C Installation and Service Manual

 

 

C

C

o

o

p

p

y

y

r

r

i

i

g

g

h

h

t

t

 

 

P

P

o

o

w

w

e

e

r

r

w

w

a

a

v

v

e

e

 

 

T

T

e

e

c

c

h

h

n

n

o

o

l

l

o

o

g

g

i

i

e

e

s

s

,

,

 

 

I

I

n

n

c

c

.

.

,

,

 

 

F

F

e

e

b

b

r

r

u

u

a

a

r

r

y

y

 

 

2

2

0

0

0

0

3

3

.

.

 

 

A

A

l

l

l

l

 

 

r

r

i

i

g

g

h

h

t

t

s

s

 

 

r

r

e

e

s

s

e

e

r

r

v

v

e

e

d

d

A

A

l

l

l

l

 

 

s

s

p

p

e

e

c

c

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

 

 

a

a

r

r

e

e

 

 

s

s

u

u

b

b

j

j

e

e

c

c

t

t

 

 

t

t

o

o

 

 

c

c

h

h

a

a

n

n

g

g

e

e

 

 

w

w

i

i

t

t

h

h

o

o

u

u

t

t

 

 

n

n

o

o

t

t

i

i

c

c

e

e

.

.

 

 

C

C

o

o

n

n

t

t

a

a

c

c

t

t

 

 

t

t

h

h

e

e

 

 

f

f

a

a

c

c

t

t

o

o

r

r

y

y

 

 

f

f

o

o

r

r

 

 

c

c

o

o

m

m

p

p

l

l

e

e

t

t

e

e

 

 

p

p

e

e

r

r

f

f

o

o

r

r

m

m

a

a

n

n

c

c

e

e

 

 

d

d

a

a

t

t

a

a

.

.

044-xxxxx Rev. A

1-1

February 2003

Section 1  General Description

1-1 

 

Introduction

This manual contains information and procedures for installation, operation, and maintenance of
Powerwave’s SPA 9321-30C (Nortel Model No. NTQA50GA) single-channel PCS amplifier. The
manual is organized into six sections as follows:

Section 1. General Description
Section 2. Installation
Section 3. Operating Instructions
Section 4. Principles of Operation
Section 5. Maintenance
Section 6. Troubleshooting

1-2 

 

General Description

The SPA 9321-30C (see figure 1-1) is a single-channel power amplifier that operates in the 60
MHz frequency band from 1930 MHz to 1990 MHz. It is designed for use in an amplifier system
that is modular in design, and is ideally suited for use in GSM/EDGE base stations. The amplifier
is capable of transmitting at 30 watts of power in either GSM or EDGE modulation. All
solid-state, the amplifier is designed to provide trouble-free operation with minimum mainte-
nance. The system's modular construction and unique and highly effective operational status and
fault monitoring circuitry help minimize downtime. The turn-on and turn-off sequences of volt-
ages are fully automatic, as is overload protection.

Each amplifier module has an I/O connector that allows the host system to monitor the amplifier
module performance. Primary power for the amplifier is –48 Vdc. The amplifier has an integrated
heat sink for cooling.

1-3 

 

Functional And Physical Specifications

Functional and physical specifications for the amplifier are listed in table 1-1.

1-4 

 

Equipment Changes

Powerwave Technologies, Inc. reserves the right to make minor changes to the equipment, in-
cluding but not necessarily limited to component substitution and circuitry changes. Changes that
impact this manual may subsequently be incorporated in a later revision of this manual.

Summary of Contents for SPA 9321-30C

Page 1: ...1930 1990 MHz Copyright Powerwave Technologies Inc February 2003 All rights reserved 044 xxxxx Rev A February 2003 Model SPA 9321 30C Single Channel PCS Amplifier Installation Service Manual...

Page 2: ...CA 92705 Fax 714 466 5800 Web Site www powerwave com 2003 Powerwave Technologies Incorporated All rights reserved Powerwave Technologies and the Powerwave logo are registered trademarks Powerwave Tech...

Page 3: ...and Inspection 2 1 2 4 Installation Instructions 2 2 2 5 Amplifier Module Connectors 2 2 2 5 1 Data I O Connector 2 3 2 5 2 Amplifier RF Connectors 2 4 2 5 3 DC Power Connector 2 4 Section 3 Operatin...

Page 4: ...Shipment 6 1 List Of Illustrations Figure Page No No 1 1 SPA 9321 30C Amplifier 1 3 2 1 SPA 9321 30C Front Panel View 2 2 2 2 Data I O Connector 2 3 2 3 DC Power Connector 2 4 3 1 Front Panel Indicat...

Page 5: ...nel power amplifier that operates in the 60 MHz frequency band from 1930 MHz to 1990 MHz It is designed for use in an amplifier system that is modular in design and is ideally suited for use in GSM ED...

Page 6: ...watts maximum RF Gain at 1960 MHz 48 0 5 dB Gain Variation Over All Conditions 2 0 dB Output Protection Mismatch Protected Input Port Return Loss 16 dB Min Out of Band Spurious 50 dBc max Spectral Mas...

Page 7: ...er rv ve ed d A Al ll l s sp pe ec ci if fi ic ca at ti io on ns s a ar re e s su ub bj je ec ct t t to o c ch ha an ng ge e w wi it th ho ou ut t n no ot ti ic ce e C Co on nt ta ac ct t t th he e f...

Page 8: ...amplifier has an internal fuse so a failure in one does not shut off the whole installation 2 3 Unpacking And Inspection This equipment has been operated tested and calibrated at the factory Only in...

Page 9: ...plifier Refer to section 2 5 1 WARNING Turn off external DC power before connecting DC power cables Verify that the amplifier is terminated into a proper 50 Ohm load 5 Connect the DC power cable to th...

Page 10: ...re listed and described in table 2 1 Figure 2 2 Data I O Connector on Front Panel Table 2 1 Data I O Connector Pin Definition Pin Function Description 1 Ground Ground 2 Ground Ground 3 Synchro Signal...

Page 11: ...ified in table 1 1 The RF Output connector is Type N female They are listed and described in table 2 2 Table 2 2 Amplifier RF Connector Definition Function Description RF Input SMA Female RF Output Ty...

Page 12: ...s 3 3 Initial Start Up And Operating Procedures To perform the initial start up proceed as follows 1 Verify that all input and output cables are properly connected CAUTION Before applying power make s...

Page 13: ...ual for detailed instructions 4 3 RF Output Load The load impedance should be as good as possible 1 5 1 or better in the working band for good power transfer to the load 4 4 SPA 9321 30C Amplifier The...

Page 14: ...converter to supply internal circuitry with 27 VDC and 5 VDC 4 4 4 Multifunction Board The multifunction board enables communication between the amplifier and the base transceiver station in which it...

Page 15: ...ll rights reserved 044 xxxxx Rev A 5 1 February 2003 Section 5 Maintenance 5 1 Introduction The amplifier is designed to be operated without any required periodic maintenance other than maintenance wh...

Page 16: ...ested Action LED not lit 1 Check that rack power connection is secure 2 Check for proper power supply voltage 3 Check that power switch is ON position LED is red 1 Verify amplifier is enabled 2 A larg...

Page 17: ...reserved 044 xxxxx Rev A 6 2 February 2003 To ensure safe shipment of the amplifier it is recommended that the package designed for the amplifier be used The original packaging material is reusable If...

Reviews: