SPECIFICATIONS CONT.
SINERGY III UPS (100 - 120 Volt UPS’s) specifications cont.
Front Panel Controls
1.
ON / MUTE - UP KEY (Previous Selection)
2.
SELECT - DOWN KEY (Next Selection)
3.
OFF / ENTER - CONFIRM KEY
Front Panel Display
Rear Panel Information and Controls
6 Foot Line Cord with NEMA 5-20P
(17201-01R Only, 1600 W Capability)
6 Foot Line Cord with NEMA L5-20P
(17201-02R Only, 1600 W Capability)
6 Foot Line Cord with NEMA L5-30P
(17201-03R Only, 1800 W Capability)
(2) NEMA 5-20R
(1) NEMA L5-20R Direct
(2) NEMA 5-15R Programmable
USB & RS-232 Communication
SNMP Adapter (Optional)
Internal Relay Contact Card (Optional)
Circuit Breaker
Internal Batteries
User Hot-Swappable (See Instruction Manual)
Type - 12 V, 8.5 AH
Quantity - 4 Batteries
Recharge time - 12 Hours to 100%
Environmental
Temperature: 0 to 40
0
C (32 to 104
0
F) Operating
-20
to
50
0
C (-40 to 122
0
F) Shipment,
Storage
Humidity:
<90% Non-Condensing (Operating,
Shipment, Storage)
Altitude:
<1000m Operating, No De-Rating
>1000m De-Rate Output 1% per 100m
Safety Agency and EMC Compliance
All units are listed by UL, and marked with the UL/cUL
marking.
Product Listings
UL1778
cUL to CSA22.2 No.107.1
Products Compliances
FCC Part 15J Class A
IEC61000-4-2, Electrostatic Discharge
IEC61000-4-3, Radiated Electromagnetic Field Immunity
IEC61000-4-4, Electrical Fast Transient/Burst Immunity
IEC61000-4-5, Surge Immunity
IEC61000-4-6, CS
IEC61000-4-8, Power Frequency Magnetic Field
IEC61000-2-2, Low Frequency Signal
RoHS
Battery
Load
Input/
Output &
Battery
UPS
Status
Warning /
Fault Info &
Setting
Operation
Backup
Time
Warranty/Support:
Sinergy III Series products (hereafter referred to as “Product”) are warranted to be free from defects in material and work-
manship for
two (2) years
from date of shipment from POWERVAR, on the chassis & electronic components and
two (2) years
from date of
shipment from POWERVAR on the batteries. This warranty is limited to repairing, replacing, or refurbishing, at POWERVAR’s option, any defec-
tive component, circuit board or module within the Product. This warranty will include, at POWERVAR’s sole discretion, on-site service or
POWERVAR depot service. See the Limitations of Warranty section below for additional limitations & exclusions.
Battery Life Disclaimer
: POWERVAR’s standard battery warranty applies only to UPS and UPM products which are continuously connected to
AC mains power, except during utility power outages. Products which are regularly and intentionally disconnected from AC mains power will ex-
perience battery discharge/charge cycles potentially far more numerous than those for which the battery was designed. As a result, products used
in such applications will experience substantially reduced battery life. For that reason, POWERVAR’s standard battery warranty does not apply for
applications in which the UPS or UPM product is regularly and intentionally disconnected from AC mains power. POWERVAR UPS and UPM
products used in such applications shall receive a 90 day warranty on batteries.
POWERVAR, Inc. -
1450 Lakeside Drive, Waukegan, IL 60085
POWERVAR, Ltd. -
Unit 5 Birch, Kembrey Park, Swindon, Wiltshire, UK SN2 8UU
11/2013 REV.
D
A03-00098