background image

Specifications

Panel Dimensions

315mm W x 925mm L x 22mm Thick

Panel 

15 watts per panel, 14.5 volts output (working)

Peak Voltage

23.5 Voc (Open Circuit Volts)

Nominal Voltage

14.5 volts battery output

Adaptor Outlets from regulator

3 VDC, 6 VDC, 12 VDC, 12 VDC
USB output

12VDC female CLA output

Inverter female CLA output (for 12V inverter)

Accessory

2 pcs of 5W 12VDC energy saving lamp

Multi purpose wire

Battery clamp wire

Save This Manual

You will need the manual for the safety warnings and precautions, assembly instructions, operating and maintenance

procedures, parts list and diagram. Keep your invoice with this manual. Write the invoice number on the inside of the front

cover. Keep the manual and invoice in a safe and dry place for future reference.

Safety Warnings and Precautions

WARNING: When using product, basic safety precautions should always be followed to reduce the risk of

personal injury and damage to equipment.

Read all instructions before using this product!

1. Keep work area clean.

 

Cluttered areas invite injuries.

2.

 

Observe work area conditions

.

 

Do not use the Regulator in damp or wet locations. Don’t expose Regulator to rain.

Do not use electrically powered products in the presence of flammable gases or liquids.

3.

 

Keep children away

. Children must never be allowed in the work area. Do not let them handle product, accessories, or

cords.

4.

 

Store idle equipment

.

 

When not in use, products must be stored in a dry location to inhibit rust. Always lock up

products and keep out of reach of children.

5. Use the right product for the job.

 

Do not attempt to force a small product to do the work of a larger industrial

product. There are certain applications for which this product was designed. It will do the job better and more safely at the

rate for which it was intended. Do not modify this product and do not use this product for a purpose for which it was not

intended.

6. Dress properly.

 

Do not wear loose clothing or jewelry as they can be caught in parts during installation. Protective,

electrically nonconductive clothes and nonskid footwear are recommended when working. Wear restrictive hair covering to

contain long hair.

7.

 

Use eye protection

. Always wear ANSI-approved impact safety goggles during assembly and when working with tools

and equipment.

8.

 

Do not overreach

. Keep proper footing and balance at all times. Do not reach over or across wires or cables.

9.

 

Maintain products with care

. Keep products clean for better and safer performance. Follow instructions for changing

accessories. Inspect product cords periodically, and if damaged, have them repaired by an authorized technician. The panels

must be kept clean, dry, and free from oil and grease at all

 

times.

10.

 

Disconnect power

. Unplug from accessories or batteries when not in use and disconnect the 

Summary of Contents for MP-4554

Page 1: ...LAR KIT INSTRUCTION MANUAL MP 4554 Distributed by Electus Distribution Pty Ltd 320 Victoria Road Rydalmere NSW 2116 Australia Phone 1300 738 555 Facsimile 1300 738 500 www electusdistribution com au Made in China ...

Page 2: ... in the work area Do not let them handle product accessories or cords 4 Store idle equipment When not in use products must be stored in a dry location to inhibit rust Always lock up products and keep out of reach of children 5 Use the right product for the job Do not attempt to force a small product to do the work of a larger industrial product There are certain applications for which this product...

Page 3: ...16 Maintenance For your safety service and maintenance should be performed regularly by a qualified technician Warning The warnings cautions and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur It must be understood by the operator that common sense and caution are factors which cannot be built into this product but must be suppli...

Page 4: ... connected to each other and the Regulator 2 again making sure you are hooking up to the right polarity on the Regulator See Hook Up Diagram right Figure 1 Operation Note Performance of the Solar Panels will vary dependent on site location angle of the panels in relation to the arc of the sun and available sunlight Recharging a Battery not included 1 To recharge a 12 volt battery not included payi...

Page 5: ...tery not included goes too high above 14 5 volts the Regulator 2 will automatically shut off power input to prevent damage to the battery not included C Overload Protection If the output current exceeds 4 amps the fuse See FIGURE 1 will blow to prevent damage to the controller in the Regulator 2 If this occurs have an authorized service technician replace the fuse Note The On Off switch of the cha...

Page 6: ...et 6 Operate your appliance 7 When finished unplug the Multi Purpose Adaptor 5 wire plug from the Regulator 2 and then unplug the Multi Purpose Adaptor 5 from the appliance Maintenance When servicing the Solar Panels Regulator or Accessories first disconnect the cable from the Regulator to the Solar Panels 1 Periodically gently clean the surface of the Solar Panels with a wet soft cloth 2 Check th...

Reviews: