During parameter entry, mistakes may be made. The
DIGIMAX
DIGIMAX
DIGIMAX
DIGIMAX
DIGIMAX
®
monitors the input
values, and if the value is proper for the current parameter or mode of operation, the value
will be accepted and the parameter table changed. VALUES MAY NOT BE IMPLEMENTED
IMMEDIATELY IF TO DO SO WOULD UPSET THE CURRENT OPERATING SITUATION.
The
DIGIMAX
®
will not put into effect immediately parameters which will radically alter the
current operation, such as changing the PPR rate (parameter #5) while the motor is running.
A stop cycle must be concluded before some parameters will become effective.
NOTE:
WHILE THE
DIGIMAX
DIGIMAX
DIGIMAX
DIGIMAX
DIGIMAX
®
®
®
®
®
IS DEALING WITH AN ERROR CONDITION, THE
ONLY FUNCTION WHICH WILL OPERATE IS EMERGENCY STOP! ERROR MES-
SAGES SHOULD BE CLEARED IMMEDIATELY IF THE
DIGIMAX
DIGIMAX
DIGIMAX
DIGIMAX
DIGIMAX
®
®
®
®
®
IS IN OPERA-
TION. ERROR MESSAGES WILL AUTOMATICALLY TIME OUT IN SIX SECONDS.
A table of error codes is presented above and explanations follow. Some of these
codes apply to specific parameters, and others are general. Section 3 gives some of the error
codes with illegal values in parameter entries.
ERROR CODE 01 -- SPEED GREATER THAN PARAMETER P-2
SPEED GREATER THAN PARAMETER P-2
SPEED GREATER THAN PARAMETER P-2
SPEED GREATER THAN PARAMETER P-2
SPEED GREATER THAN PARAMETER P-2
This error comes up in the MASTER mode when a new speed command is entered.
The speed entered is greater than the P-2 parameter. Press ENTER to clear the error code
and then reenter the speed command. If this speed is necessary, parameter #2 may have
to be changed. Make sure it is within the speed range of the motor.
CODE
MEANING
CODE
MEANING
00
no error (not displayed)
11
illegal up/down increment value
01
Speed greater than parameter #2
12
0 integer value not allowed
02
Acceleration ramp time too small
13
Parameter change not allowed
03
Deceleration ramp time too small
14
Jump up/dn value too large
04
Value greater than 255
15
Illegal attempt to change parameter
05
Value greater than 65535
16
illegal protocol number
06
Value greater than 99999
17
maximum ratio exceeded
07
Illegal decimal location
18
maximum ramp value exceeded
08
Illegal unit I.D.
19
illegal parameter number
09
Illegal mode value
20
maximum parameter value
10
Illegal baud rate
21
less than minimum ratio
99
unknown error
Table 2: Error codes for the
DIGIMAX
DIGIMAX
DIGIMAX
DIGIMAX
DIGIMAX
®
.....