background image

DUST COLLECTOR PARTS LIST

PARTS LIST

11

11

Key. No.  Part. No.

Description 

Specification

Q'ty

1

DC1080001

Base

1

2

DC1080002

Caster

4

3

DC1080003

Nut

5/16"

4

4

DC1080004

Collector Body

1

5

DC1080005

Hex.Screw

M6x20

1

6

DC1080006

Impeller Washer 

 

1

7

DC1080007

Impeller

1

8

DC1080008

Hex. Head Screw 

5/16''X5/16''

1

9

DC1080009

Flanger screw

1/4" x 1/2"

4

10

DC1080010

washer 

1/4"x25

4

11

DC1080011

Inlet cover

1

12

DC1080012

Round head cross screw

M5x10mm

12

13

DC1080013

Motor Packing

1

14

DC1080014

Key

6x6x25

1

15

DC1080015

Motor

1

16

DC1080016

handle

 

1

17

DC1080017

handle cap

5/8"

2

18

DC1080018

Philip Head Screw

5/16"x1"

2

19

DC1080019

Form Grip

 

1

20

DC1080020

Supporting Leg

 

2

21

DC1080021

Hex.Head Screw

5/16"x1/2"

12

22

DC1080022

Supporter

1

23

DC1080023

Hanger

1

24

DC1080024

Upper Filter Bag

1

25

DC1080025

Bottom Collecting Bag

1

26

DC1080026

Power Cord

 

1

27

DC1080027

Switch

1

28

DC1080028

Foam

 

1

29

DC1080029

Washer 

5/16"

4

30

DC1080030

Bag Clamp

 

2

31

DC1080031

Foam 

1

32

DC1080032

Open End Wrench

10-12 mm

1

Summary of Contents for DC1080

Page 1: ...will need this manual for safety instructions operating procedures and warranty Put it and the original sales invoice in a safe dry place for future reference Visit us on the web at www southerntechllc com Dust Collector QUESTION 1 847 780 6120 ...

Page 2: ...e level measuring no load Operators position 83dB a weighted sound pressure level measuring loaded 85dB TABLE OF CONTENTS PRODUCT SPECIFICATIONS SAFETY RULES 1 Work Preparation Work Area Preparation Tool Maintenance Tool Operation Specific Safety Instructions ASSEMBLY 2 Unpacking Installation Test Power Source Grounding Instructions Extension Cords Motor Electrical Connections OPERATION 7 Basic Op...

Page 3: ...ons Do not expose power tools to rain Work area should be properly lit Ground all tools Proper electrical receptacle should 1 SAFETY RULES be available for tool Three prong plug should be plugged directly into properly grounded three prong receptacle If an adapter is used to accomodate a two prong receptacle the adapter lug MUST be to a known ground Extension cords should have a grounding prong an...

Page 4: ...le or combustible dust gas DO NOT use near any flammable or combustible liquids Never attempt to use this dust collector to collect anything that is burning or smoking DO NOT use outdoors or on wet surfaces Turn machine off disconnect power cord and ensure all moving parts have stopped completely before servicing or changing emptying the bags Always wear approved eye protection and respirator when...

Page 5: ...the 12 mm wrench to tighten hardware Figure 2 Caster Nut Washer 2 Lay the collection body upside down on a protective surface as shown Figure 3 Collection Body 3 Attach the two rectangular supports to the collection body using the 5 16 x 1 2 hex head screws use the 12 mm wrench to tighten hardware Figure 4 Collection Body Rectangular Supports 5 16 X 1 2 Hex Head Screws 5 16 X 1 2 Hex Head Screws 4...

Page 6: ...ure 11 Collection Body Upper Bag Support 11 Thread the bag clamp through the hemmed opening in the bottom of the filter bag Figure 12 Bag Clamp Hemmed Opening Filter Bag 12 Place the filter bag over the upper bag support on to the collection body and fasten the bag clamp 13 Place the adhesive foam strip supplied around the lower opening of the collection body Figure 13 Bag Clamp Collection Body Fi...

Page 7: ...nection of equipment grounding conductor can result in the risk of electrical shock Equipment should be grounded while in use to protect operator from electrical shock Check with a qualified electrician if you do not understand grounding instructions or if you are in doubt as to whether the tool is properly grounded This tool is equipped with an approved cord rated at 120V and a 3 prong grounding ...

Page 8: ...VERT TO 240V POWER SUPPLY To convert the dust collector to 240V the switch box must be rewired and a new plug attached A qualified electrician MUST inspect the switch box and new plug before the dust collector is connected to the power source The 240V power supply circuit must have a verified ground and meet these requirements Circuit Type 220V 240V 60 Hz Single Phase Circuit Size 15 Amps Plug Rec...

Page 9: ...f reach of children WARNING ALWAYS lock the switch OFF when the dust collector is not in use Remove the key and keep it in a safe place In the event of power failure blown fuse or tripped circuit breaker turn the switch OFF and remove the key preventing accidental startup when power comes on OPERATION 7 Figure 19 Yellow Switch Key On Off Switch Operation NOTE This dust collector is designed to col...

Page 10: ...NCE 8 MAINTENANCE 8 LUBRICATION The sealed bearings in the motor have been permanently lubricated at the factory They require no further lubrication MACHINE STORAGE When the dust collector is not in use disconnect the cord from the power source and store the machine in a dry place Do not expose the machine to rain Ensure the cord is kept away from potential damage sources such as sharp objects che...

Page 11: ...r mount is loose broken 3 Motor fan is rubbing cover 4 Motor bearings faulty 5 Dust collector is not on a flat surface 1 Inspect replace any stripped or damaged bolts nuts and re tighten 2 Tighten replace 3 Replace fan cover replace loose damaged fan 4 Call the customer service line at 847 780 6120 for assistance 5 Place the dust collector on a flat surface Loud repetitious noise or excessive vibr...

Page 12: ...DUST COLLECTOR PARTS ILLUSTRATION 10 PARTS LIST 10 ...

Page 13: ...DC1080012 Round head cross screw M5x10mm 12 13 DC1080013 Motor Packing 1 14 DC1080014 Key 6x6x25 1 15 DC1080015 Motor 1 16 DC1080016 handle 1 17 DC1080017 handle cap 5 8 2 18 DC1080018 Philip Head Screw 5 16 x1 2 19 DC1080019 Form Grip 1 20 DC1080020 Supporting Leg 2 21 DC1080021 Hex Head Screw 5 16 x1 2 12 22 DC1080022 Supporter 1 23 DC1080023 Hanger 1 24 DC1080024 Upper Filter Bag 1 25 DC1080025...

Page 14: ... proof of purchase documentation which includes a date of purchase POWERTEC will either repair or replace any defective part at our option at no charge to you The repaired or replacement unit will be covered by the same limited warranty for the balance of one year warranty period WHAT IS NOT COVERED This warranty applies to the original purchaser at retailer and may not be transferred This warrant...

Page 15: ......

Page 16: ...Southern Technologies LLC 3816 Hawthorn CT Waukegan IL 60087 ...

Reviews: