RF 400/410/2000 Page 4
MAXIMUM TEMPERATURE SETTING
(refer to
Figure 7
).
This mus
t
be set on the job and following any maintenance
or servicing to the valve. Mixer is factory set to pass full
HOT water.
a. Loosen adjustment stop screw (do not remove).
Gradually rotate stem counterclockwise to get desired
maximum water temperature. (Maximum Temperature
Stop will rotate long with the stem when the stem is
rotated).
b. Once stem has been rotated to desired temperature,
slide adjustment stop clockwise until fin on adjustment
stop touches the maximum temperature stop.
c. While holding adjustment stop in place, tighten adjust-
ment stop screw.
d. Replace handle. Confirm maximum temperature has been
set properly by operating the valve using the handle.
Caution: Adjustment stop must be present for proper
operation.
MAXIMUM TEMPERATURE SETTING/HANDLE ROTATION STOP
Figure 7
: Maximum Temperature Setting
RF 400/410/2000 0648
EDP# 6508770
© 2006 Powers
USA:
Phone: 1.800.669.5430 • Fax 1.847. 229 . 0526 • www.powerscontrols.com
Canada:
Phone: 1.888.208.8927 • Fax 1. 888. 882 .1979 • www.powerscontrols.ca