www.powermaxfitness.net
14
5.
FAT
≤19
Under weight
FAT = (20---25) Normal weight
FAT = (25---29) Over weight
FAT
≥30
Obesity
Error Code Meaning
Fault code Failure Description
fault handling
E1
Communication
Abnormal: when the
power on, the connection
between lower controller
and the console is
abnormal.
Possible Cause:
the communication between the lower controller and
console is blocked, check each joint between the
controller and console, ensure that each terminal is
fully matched well. Check the connection line, replace
it if it’s damaged.
E2
No signal from motor.
Possible Cause:
Check the cable between the motor and drive board to
see whether it is connected well or not, if not, connect
it well.
Check the motor cable to see whether it is damaged or
has a burnt smell, if yes, replace the motor.
E5
Over current protection:
In working, the lower
controller detects the
current to be over 6A for
more than 3 seconds.
Possible Cause:
Overloading leads to excessive current, and the system
stop for self-protection, or some part of treadmill is
stuck, causing the motor to stop. Adjust the treadmill
and restart it. Check if there is over current sound or
burnt smell while the motor is running, if yes, replace
the motor; check if the controller has a burned smell, if
yes, replace the controller; check the power supply
voltage, if it does not match or under the
specifications, use correct voltage to test the machine
again.
E6
Explosion-proof impact
protection: the power
supply voltage abnormal
or motor abnormal cause
the faulty of circuit while
drive the motor.
Possible Cause:
Check if the power supply voltage is 50% lower than
normal voltage, use the correct voltage and test the
machine again
;
check if the lower controller has a burnt smell, if yes,
replace the controller;