PowerMax ASE59 User Manual Download Page 3

3/8

 

Key Name 

Description 

 

End back tacking 

setting key

 

Switch during all end tacking type when press the

  key is lit.(No tacking, once tacking, 

double tacking, 4 repeat tacking). Show 

  is end back tacking interface,default range 

1~F corresponds to the 1~15 pin. 

 

W sewing   

The system enter to W sewing mode when press the

 key is lit. Show 

 is w 

sewing interface,default range 1~F corresponds to the 1~15 pin.

 

 

Multi-section 

constant-stitch 

sewing

 

The system enter to multi-section constant-stitch sewing mode when press the 

  key is lit. 

Show 

is multi-section constant-stitch sewing interface, Use

key and

key to 

adjustment Increasing and decreasing value. Default maximum range 15. 

 

Soft start setting key

 

Soft start at the first seam is enabled (the 

key is lit ) or disabled. 

 

Stop position key

 

Select up/down stop position.Press

key is lit that is called up stop position. Press

key 

again ,the lights went out that is called down stop position. 

 

Trimming cycle   

selection 

Enable or disable the trimming cycle.the

key is lit when the automatic trimming. 

 

Presser foot lifting 

Mode

 

Switch during all presser foot lifting mode when pressing the 

key is lit. (No lifting, lifting 

after trimming cycle only,  lifting at machine stop only, lifting at machine stop and after 

trimming cycle both). 

 

One-shot-sewing 

selection 

 

In constant-stitch sewing

a. Press the

key is lit, automatic performed number of stitches of 

every section. 

b. Press

key again ,the lights went out to finish rest the sections until it finish pattern. 

 

Custom function key 

Special function according to the custom requirement. 

 

Up  keys 

Adjust the values in plus state. In addition, when the parameter is set, it can be used as the 

key to adjust the corresponding parameters.

 

 

 Down keys

 

Adjust the values minus state.

 

In addition, when the parameter is set, it can be used as the 

key to adjust the corresponding parameters. 

3 System Parameters Setting List 

3.1 Technician Mode 

NO. Range 

Default 

Description 

1

Long press

P

key can modify the technical parameter table; 

2、

The digital tube display

It is required to enter password to the technical parameter. Press the corresponding 

key and

key to change the password value;

 

3

Press

P

key, If the password is correct, that is to enter the technical parameters set mode,show P1 0 0.Press

key, the current 

parameter value is displayed; 

Summary of Contents for ASE59

Page 1: ... manual carefully also with related manual for the machinery before use the controller For installing and operating the controller properly and safely qualified personnel are required Please try to stay away from arc welding equipment in order to avoid electromagnetic interference and malfunction of the controller Keep in room bellow 45 and above 0 Do not humidity below 30 or above 95 or dew and m...

Page 2: ...ssive distortion to ensure safe use 2 Operation Panel Instructions 2 1 Operation Panel Display Instruction Fig 2 1 Operation Panel Key Functions Key Name Description Parameter setting key Use the key to switch to the program mode The key is parameters confirm key and back to the previous menu until the operator sewing mode state In addition work with other key to set a higher level of the paramete...

Page 3: ...ting Mode Switch during all presser foot lifting mode when pressing the key is lit No lifting lifting after trimming cycle only lifting at machine stop only lifting at machine stop and after trimming cycle both One shot sewing selection In constant stitch sewing a Press the key is lit automatic performed number of stitches of every section b Press key again the lights went out to finish rest the s...

Page 4: ...B none 4 AB ABAB none 1 1 C 0 9999 0 Tens digit for each segment of A B C D 1 1 D 0 9999 0 Tens digit for each segment of E F G H 1 1 E 0 9999 0 Tens digit for each segment of A B D 1 1 F 0 359 0 Back tacking under angle control 1 3 0 0 1 2 3 2 Speed curve adjustments 0 ramp curve 1 polygonal curve 2 quadric curve 3 S type curve 1 3 1 200 4000 3000 The turning point speed of two segment curve 1 3 ...

Page 5: ...en count over panel alarms and motor stops after trimming 6 Count down by trimming When count over panel alarms and motor stops after trimming 1 5 3 1 100 1 The proportion coefficient of the pieces counter 1 5 4 1 9999 1 Maximum pieces of the counter 1 5 5 0 4 0 Count mode selection For Sewing Piece 0 The counter is invalid 1 Count up by pieces When count over counter will be auto reset 2 Count do...

Page 6: ...ead release output end angle LE Down needle position angle is the reference and this value should be bigger than LS 2 1 3 1 999 1 Thread release output start delay time T1 ms 2 1 4 1 999 10 Thread release output end delay time T2 ms after up needle position 2 1 5 0 1 1 Wiper function 0 disable 1 enable 2 1 6 1 999 10 Wiper output delay time ms 2 1 7 1 9999 70 Wiper output time ms 2 1 9 0 1 0 Threa...

Page 7: ...r still does not work please replace it and inform the manufacturer E r r 0 3 Under voltage Check mains voltage Stabilize mains voltage E r r 0 4 Over voltage when the machine is off E r r 0 5 Over voltage in operation Disconnect the controller power and check if the input voltage is too high higher than 264V If yes please restart the controller when the normal voltage is resumed If the controller...

Page 8: ...wn simultaneously 3 2 4 0 0 0 0 Step 3 Press P key the new up needle position is preserved and the parameter is set to zero 4 2 The Recovery of Default Factory Setting 1 2 4 0 0 0 0 Step 1 Press P key then enter the monitor mode 2 Step 2 Press key for about 5 seconds then Default Factory Setting is recovered displaying as left LCD 3 8 8 8 8 8 8 When the LCD is displayed as 8888888 the recovery is ...

Reviews: