Fig.1-2 Controller Interface Definition 

1.3 Wiring and Grounding 

We must prepare the system grounding project, please a qualified electrical engineer to be construction. Product is energized and 

ready for use; you must ensure that the power outlet the AC input is securely grounded. The grounding wire is yellow and green lines, 

it must be connected to the grid and reliable security protection on the ground to ensure safe use, and prevent abnormal situation. 

All power lines, signal lines, ground lines, wiring not to be pressed into other objects or excessive distortion, to ensure safe 

use! 

2 Operation Panel Instructions 

2.1 

Operation Panel Display Instruction 

 

 

 

 

 

 

Fig.2-1 Operation Panel                                                 

   

Key Functions 

Key Name 

Description 

 

Parameter setting key

Use the key to switch to the program mode.The key is parameters confirm key, and back to 

the previous menu until the operator sewing mode state. In addition, work with other key to 

set a higher level of the parameter. 

 

Parameter 

modification  key 

Parameter to modify the confirmation key, press the 

  again to return to the standby 

interface. 

 

Start back tacking 

setting key

 

Switch during all start tacking type when press the

  key is lit. (No tacking, once tacking, 

double tacking, 4 repeat tacking). Show 

  is start back tacking interface,default range 

1~F corresponds to the 1~15 pin. 

Summary of Contents for ASE59

Page 1: ... manual carefully also with related manual for the machinery before use the controller For installing and operating the controller properly and safely qualified personnel are required Please try to stay away from arc welding equipment in order to avoid electromagnetic interference and malfunction of the controller Keep in room bellow 45 and above 0 Do not humidity below 30 or above 95 or dew and m...

Page 2: ...ssive distortion to ensure safe use 2 Operation Panel Instructions 2 1 Operation Panel Display Instruction Fig 2 1 Operation Panel Key Functions Key Name Description Parameter setting key Use the key to switch to the program mode The key is parameters confirm key and back to the previous menu until the operator sewing mode state In addition work with other key to set a higher level of the paramete...

Page 3: ...ting Mode Switch during all presser foot lifting mode when pressing the key is lit No lifting lifting after trimming cycle only lifting at machine stop only lifting at machine stop and after trimming cycle both One shot sewing selection In constant stitch sewing a Press the key is lit automatic performed number of stitches of every section b Press key again the lights went out to finish rest the s...

Page 4: ...B none 4 AB ABAB none 1 1 C 0 9999 0 Tens digit for each segment of A B C D 1 1 D 0 9999 0 Tens digit for each segment of E F G H 1 1 E 0 9999 0 Tens digit for each segment of A B D 1 1 F 0 359 0 Back tacking under angle control 1 3 0 0 1 2 3 2 Speed curve adjustments 0 ramp curve 1 polygonal curve 2 quadric curve 3 S type curve 1 3 1 200 4000 3000 The turning point speed of two segment curve 1 3 ...

Page 5: ...en count over panel alarms and motor stops after trimming 6 Count down by trimming When count over panel alarms and motor stops after trimming 1 5 3 1 100 1 The proportion coefficient of the pieces counter 1 5 4 1 9999 1 Maximum pieces of the counter 1 5 5 0 4 0 Count mode selection For Sewing Piece 0 The counter is invalid 1 Count up by pieces When count over counter will be auto reset 2 Count do...

Page 6: ...ead release output end angle LE Down needle position angle is the reference and this value should be bigger than LS 2 1 3 1 999 1 Thread release output start delay time T1 ms 2 1 4 1 999 10 Thread release output end delay time T2 ms after up needle position 2 1 5 0 1 1 Wiper function 0 disable 1 enable 2 1 6 1 999 10 Wiper output delay time ms 2 1 7 1 9999 70 Wiper output time ms 2 1 9 0 1 0 Threa...

Page 7: ...r still does not work please replace it and inform the manufacturer E r r 0 3 Under voltage Check mains voltage Stabilize mains voltage E r r 0 4 Over voltage when the machine is off E r r 0 5 Over voltage in operation Disconnect the controller power and check if the input voltage is too high higher than 264V If yes please restart the controller when the normal voltage is resumed If the controller...

Page 8: ...wn simultaneously 3 2 4 0 0 0 0 Step 3 Press P key the new up needle position is preserved and the parameter is set to zero 4 2 The Recovery of Default Factory Setting 1 2 4 0 0 0 0 Step 1 Press P key then enter the monitor mode 2 Step 2 Press key for about 5 seconds then Default Factory Setting is recovered displaying as left LCD 3 8 8 8 8 8 8 When the LCD is displayed as 8888888 the recovery is ...

Reviews: