background image

 

22

This page intentionally left blank 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PM1300TX

Page 1: ...X with Filter Bag Kit 1791078K PM1300TX with Canister Kit 1791079K Powermatic 427 New Sanford Road LaVergne Tennessee 37086 Part No M 1791078 Ph 800 274 6848 Revision B 05 2016 www powermatic com Copyright 2014 Powermatic Now with This pdf document is bookmarked ...

Page 2: ...ed Powermatic has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the Powermatic website More Information Powermatic is constantly adding new products For complete up to date product information check with your local distributor or visit the Powermatic website How Stat...

Page 3: ...trical Connections 12 Extension Cords 12 Overload Re set 12 Operating the Machine 13 Setting the Timer 13 Connecting the Dust Collector to a Machine 13 Maintenance 13 Cleaning the Filter Bag 13 Removing the Collector Bag 13 Cleaning the Canister Filter 14 Motor 14 Grounding Instructions 14 Replacement Parts 15 Breakdown for PM1300TX Dust Collector Base Machine 15 Parts List for PM1300TX Dust Colle...

Page 4: ...s depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as face or dust masks that are specifically designed to filter out microscopic particles 10 Do not operate this machine while tired or under the influence of drugs alcohol or any medication 11 Make certain the switch is in the OFF ...

Page 5: ...ug by pulling on cord To unplug grasp the plug not the cord 29 Do not use without dust bag and or filters in place 30 Do not handle plug or machine with wet hands 31 Do not put any objects into the openings Do not use with any opening blocked keep free of dust lint hair and anything that may reduce air flow 32 Do not operate without hose connected to the inlet Hazardous moving parts inside Unplug ...

Page 6: ...086 Impeller Diameter in 12 Sound Rating at 3 feet dB 75 90 Inlet Port Diameter in two at 4 or one at 6 Air Flow CFM 1 300 Velocity at 6 FPM 5 374 Static Pressure inch of water 11 31 Filter and Collection Bag Diameter in 20 Filter Bag Length in 34 Filter Bag Efficiency 96 of 30 micron particles Canister Length in 26 Canister Efficiency 86 of 1 micron particles 98 of 2 micron particles Collector Ba...

Page 7: ...ousing 1 T Support Bar 1 U Handle 2 V Plate 2 W Socket Head Cap Screw M8x12 4 Remote Control w batteries not shown 1 Owner s Manual not shown 1 Warranty Card not shown 1 Main Hardware Bag contents Figure 1 A M8 x 20 Hex Cap Screws 24 B M6 x 12 Pan Head Flange Screws 8 C M8 Flat Washers 34 D M10 Flat Washers 6 E M8 Hex Nuts 16 F 3 8 Hex Nuts 4 on casters G M10 Lock Washers 4 on casters Cone Assembl...

Page 8: ...sure that the holes of the mating flanges are aligned Note Refer to Figure 3 to make sure that the connector tube is facing the proper direction 3 Insert an M8x20 hex cap screw A through the M8 washer C and flanges of the connector tube O and fan housing K 4 Place another washer C and a hex nut E on the protruding end of the screw A and hand tighten only 5 Mount the control box P to the two holes ...

Page 9: ...from the handle 3 Install the second handle to the housing Cone Installation Install the cone assembly as shown in Figure 3a 1 Mount the cone support bracket AA to the housing with four M6x12 hex cap screws FF and tighten from beneath with four M6 hex nuts GG 2 Install the cone BB from beneath using the M8x16 hex cap screw CC M8 flat washer DD and M8 hex nut EE Filter System If your PM1300TX Dust ...

Page 10: ...de the hanger Figure 4 onto the hanger bracket as far down as it will go Rotate the hanger so that the hook at the top points toward the front of the machine 5 Insert the ring Figure 5 of the collector bag into the bottom of the housing at an angle Pull down on the collector bag to make sure it seats on the inner lip of the housing 6 Position the plastic window in front so that you can easily see ...

Page 11: ...ly 3 inches so that there are no air leaks 12 Remove the handle Figure 10 from inside the canister filter Mount the handle onto the canister filter with two M10 hex nuts A two M10 flat washers B and an M10 lock washer C Arrange these fasteners according to Figure 10 Tighten with a 17mm wrench 13 Place the canister on top of the housing and push down to ensure the canister is seated on the housing ...

Page 12: ...can result in a risk of electric shock The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric cord or plug is necessary do not connect the equipment grounding conductor to a live terminal The hose or ductwork you use to connect the tool to the dust collector must also be ground...

Page 13: ...is restarted the timer must be reset Connecting the Dust Collector to a Machine Use the proper type hose to connect the dust collector to the machine being operated Dryer vent hose is not acceptable for this purpose Contact your nearest Powermatic distributor for a full line of Dust Collector hoses and accessories You can customize your installation and obtain maximum performance with dust hoods h...

Page 14: ... qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt as to whether the tool is properly grounded 2 For grounded cord connected tools rated less than 15 amperes and intended for use on a nominal 120V supply circuit This tool is intended for use on a nominal 120V circuit and has a grounded plug that looks like the plug illustrated Ske...

Page 15: ...ur service department call 1 800 274 6848 Monday through Friday see our website for business hours www powermatic com Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately Breakdown for PM1300TX Dust Collector Base Machine ...

Page 16: ...embly 115 230V 1 19 1 DCRC 108 Switch Box 1 19 2 DCRC 105 Digital Switch 1 19 3 DCRC 106 Circuit Board 1 19 4 DCRC 104 Seal 1 19 5 DCRC 103 Switch Plate 1 19 6 PM1900 108 6 Pan Head Screw M5x8 4 19 7 DCRC 102 Screw 3 19 8 ST039304 Tapping Screw M3 5x12 6 19 9 DCRC 111 Tapping Screw M3 5x10 1 PM1900 108 10 Display Label not shown 1 20 PM1900 107 Mount Plate 1 21 PM1900 129 Remote Control 1 PM1900 1...

Page 17: ...0 47 1 Support Bracket 1 57 TS 1490021 Hex Cap Screw M8x16 1 58 TS 1550061 Flat Washer M8 1 59 TS 1540061 Hex Nut M8 1 60 TS 1482021 Hex Cap Screw M6x12 4 61 TS 231061 Hex Nut M6 4 PM2700 440 Wide Stripe not shown per ft PM2700 441 Narrow Stripe not shown per ft PM1300 162 Powermatic Turbocone Decal not shown 2 3 4 x8 1 PM1300 BMHP Base Machine Hardware Package not shown 1 DC1100 HP2 Hardware Pack...

Page 18: ...18 Breakdown for PM1300TX Canister Filter System ...

Page 19: ... 1550071 Flat Washer M10 2 10 331050 Handle 1 11 331051 Soft Grip Handle 2 12 TS 2361101 Lock Washer M10 1 13 BR000052 Rivet 5 2 3 14 331014 Bracket 1 15 150623 Rubber Mount 1 16 TS 1540041 Hex Nut M6 8 17 331052 Shaft 1 18 TS 1482041 Hex Cap Screw M6x20 4 19 TS 2361061 Lock Washer M6 4 20 TS 1550041 Flat Washer M6 4 21 331012 Scraper 2 22 331017 Plate 2 23 331015 Plate 2 24 TS 1482021 Hex Cap Scr...

Page 20: ... System Index No Part No Description Size Qty 1791077B PM1300 Collection and Filter Bag includes 1 thru 5 1 1 1791077F Filter Bag 30 micron 1 2 410012 Retainer Strap 1 3 708699A Collection Bag 1 4 402040 Hanger 1 5 523011 Hanger Bracket 1 ...

Page 21: ...21 Electrical Connections ...

Page 22: ...22 This page intentionally left blank ...

Page 23: ...23 This page intentionally left blank ...

Page 24: ...24 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www powermatic com ...

Reviews: