background image

 

OPERATING MANUAL BDC-44 

VERSION 1.1 

           www.blastrac.com     1-800-256-3440 

 

Summary of Contents for BDC-44

Page 1: ...OPERATING MANUAL BDC 44 VERSION 1 1 www blastrac com 1 800 256 3440 ...

Page 2: ...requirements of the European Directive for machine Safety In case of changes to the machine without our written authorization this declaration loses its validity Model Blastrac BDC 44 Serial number xxxxx 1 satisfies the conditions set out in the Machine Directive Directive 2006 42 EC Low voltage directive 2006 95 EC as last amended EMC directive 2004 108 EC as last amended 2 satisfies the followin...

Page 3: ...Safety precautions with regard to transport Safety regulations with regard to maintenance 4 Before operation 08 Checkpoints of power supply 5 Operation 08 Starting stopping the machine Work with the machine Interrupting work 6 Maintenance 09 Filter replacement Pulse system Compressor 7 Special option 11 8 Technical data 12 Contact 13 ...

Page 4: ...AA Class Designation L Low risk for separating dust with an exposure limit value of over 1 mg m3 depending on the volume occupied M BDC 44 Medium risk for separating dust with an exposure limit value of over 0 1 mg m3 depending on the volume occupied H High risk for separating al dust with an exposure limit value lower than 0 1 mg m3 depending on the volume occupied Including carcinogenic and path...

Page 5: ...Rubber impact plate 5 Manometer shows the pressure of the air tank The pulse to clean the filters must be given at 5 5 5 bar 6 Drain valve Open regular to remove water from the air tank 7 Pressure valve must be set on 5 5 5 bar 8 Air filter compressor ...

Page 6: ...he hazardous zone take precautions to prevent dust from escaping Safety precautions with regard to maintenance To allow the user to carry out maintenance operations the dust collector must be disassembled cleaned and inspected as far as reasonably possible without causing hazards for the maintenance staff or other people The suitable precautions include decontamination before disassembling the dus...

Page 7: ...connection do not change this and use always earthed cables with an earthed plug Connect the main power supply cable to an installation with an earth leakage circuit breaker Inspect and test the electrical components regularly The electrical components have to satisfy to the requirements which apply to these components Always call a skilled electrician or your distributor when you have questions a...

Page 8: ...ply Switch on the main switch Switch on first the compressor Secondly switch on the fan motor Carry out this actions in opposite sequence to stop the machine Work with the machine Regular check the contents of the dust bin Regular open the drain valve to remove water from the air tank Interrupting work When temporarily interrupting the work 1 2 hour 1 hour turn off the fan unit only Pulse cleaning...

Page 9: ... uninterrupted operation When the indicated number of working hours is not achieved during the corresponding period the period can be extended However a full overhaul must be carried out at least once a year Due to different working conditions it can t be foreseen how frequently inspections for wear check s inspection maintenance and repair works ought to be carried out Prepare a suitable inspecti...

Page 10: ...in the system is 5 5 5 bar The safety valve mounted on the compressor is activated at approximately 10 bar This provision is to ensure that when there is a defect in the Control valve the pressure in the pulse tank remains within safe limits If the pressure of 5 bar is not reached it is possible that there is a leakage in the pneumatic circuit or the air filter of the compressor is dirty When ther...

Page 11: ...rk by the use of high class hepa filter Applied by us filters have high filtration efficiency starting from just 99 95 7 2 Difference vacuum gauge A vacuum gauge measures the difference between the under pressure above the filters and inner filter house So the higher the difference pressure are the worse the filter is working This readout indicates the need to replace filters ...

Page 12: ... 4 x 16mm2 15m 4 x 6mm2 15m Available plug connections 5 pole 60 Ampere 5 pole 32 Ampere Air flow with 15m hose 5 and medium shot blaster 752m3 hr Air flow without hose 1500m3 hr Vacuum 61 mbar Dust hose connection Ø76mm Ø102mm Ø127 mm Dust bin capacity 100L Longo pack capacity 25L Dust bag 67 5L Length 1294mm Width 666mm Height 1430mm Weight 297kg Design and specifications are subject to change w...

Page 13: ... noted on shipping receipt Hand Tool Products Blastrac warrants its BLASTRAC Hand Tool Products including hand grinders and accessories against defects in material and workmanship under normal and proper use for a period of 90 days from the date of delivery or in the case of Rental Fleet Machines from the date of assignment to a Rental Fleet Blastrac makes this warranty only to the buyer who purch...

Page 14: ...motors batteries tires and all other parts See component manufacture warranty 7 Blastrac reserves the right to make product changes or improvements without prior notice and without undertaking any obligation for such changes or improvements on previously sold products 8 The above warranty conditions can only be altered by Blastrac Blastrac must confirm alterations in writing for each specific tran...

Page 15: ...e Warranty Registration IMPORTANT To ensure that your Blastrac machine is covered under warranty please provide the information recorded here by registering online at blastrac com or complete this page and fax to 866 485 1046 or if you prefer detach and mail to Blastrac 13201 North Santa Fe Avenue Oklahoma City OK 73114 9901 Please print legibly Company ____________________________________________...

Page 16: ...Blastrac 13201 North Santa Fe Avenue Oklahoma City OK 73114 800 256 3440 Fax 866 485 1046 www blastrac com ...

Reviews: