10 HP Briggs & Stratton OHV engine
*
Low oil sensor
*
Receptacles on control panel
*
Electric Start
*
CordKeeper™
*
5 gallon plastic fuel tank
*
Spark arrester
*
Portability Kit
A. 120 V, 20 Ampere Duplex Receptacle
This duplex is split so that 20 amps of current may be
drawn from each half of the receptacle. However, total power
drawn must be kept within nameplate ratings. These
receptacles may be used along with the twistlock receptacle
provided the generator is not overloaded.
B. 120/240 V, 20 Ampere Twistlock Receptacle
A maximum of 20 amps may be drawn from the 120/240
volt receptacle, provided it is the only receptacle used.
However, current must be limited to the nameplate rating. If the
120/240 volt receptacle is used along with the 120 volt
receptacle, the total load drawn must not exceed the nameplate
ratings.
C. Circuit Breakers
The receptacles are protected by an AC circuit breaker. If
the generator is overloaded or an external short circuit occurs,
the circuit breaker will trip. If this occurs, disconnect all
electrical loads and try to determine the cause of the problem
before attempting to use the generator again. If overloading
causes the circuit breaker to trip, reduce the load.
NOTE:
Continuous tripping of the circuit breaker may cause
damage to generator or equipment.
The circuit breaker may
be reset by pushing the button of the breaker.
D. 120 V, 30 Ampere Twistlock Receptacle
You may draw a maximum of 30 amps or 3600 watts from
this receptacle. If other receptacles are used at the same time,
total power used must be kept within nameplate ratings.
E. CordKeeper™
The CordKeeper™ is a unique
feature used to prevent plugs from
being pulled out of the 120-volt
receptacles.
ELECTRIC START WIRING
This model is equipped with a trickle charge system. The
red wire which comes from the engine should be connected to
the positive battery terminal (see wiring diagram).
The battery is customer provided. Copper leads are
supplied with your generator. Provide a lead from the push
button switch to the positive (+) battery terminal and a lead from
the chassis of the generator to the negative (-) battery terminal.
WARNING: Batteries contain sulfuric
acid (when filled). May contain explosive
gasses. Always abide by safety warnings
provided with the battery.
-
Keep sparks, flame and cigarettes away.
-
Hydrogen gas is generated during
charging and discharging.
-
Always shield eyes, protect skin and
clothing when working near batteries.
ELECTRIC START MODELS
BASIC WIRING DIAGRAM
2
English
CONTROL PANEL
MAJOR GENERATOR FEATURES
Summary of Contents for PMC505622
Page 11: ...11 PARTS DRAWING SCHEMA DES PI CES DIAGRAMA DE PIEZAS PMC505622...
Page 14: ...NOTES REMARQUES NOTAS 14...
Page 15: ...15...