Gaseous Fueled Stationary Standby

25

kW

60

Hz

Page 3 of 4

Fuel System

Fuel Type

Liquefied Petroleum Gas Vapor or
Natural Gas (LP Liquid Optional)

Fuel Supply Inlet

1/2” NPT

Fuel Supply Pressure

7-11 (In/H

2

O)

4-6  (Oz/In

2

)

Fuel Consumption

Fuel Consumption @ % Load

LP Gas (Cubic Feet/Hour)

Natural Gas (Cubic Feet/Hour)

25%

34

85

50%

67

169

75%

101

254

100%

135

304

Engine Generator Application/Installation Data

Radiator Airflow

4200 CFM

Alternator Airflow

250 CFM

Combustion Airflow

100 CFM

Total Airflow

4550 CFM

Heat Rejected To Coolant

70000 BTU/HR

Heat Rejected To Exhaust

195000 BTU/HR

Maximum Exhaust Flow

206 CFM

Maximum Exhaust Backpressure

1.1 PSI

Exhaust Temperature

1200 °F

Sound Data

66 

66 

66 

66 dB(A) Average @ 23’ (7m) @ Full Load

dB(A) Average @ 23’ (7m) @ Full Load

dB(A) Average @ 23’ (7m) @ Full Load

dB(A) Average @ 23’ (7m) @ Full Load

©2002 Coleman Powermate, Inc.

Coleman® is a registered trademark of the Coleman Company, Inc. used under license.

All Specifications Subject to Change Without Notice

Position 50% Load 100% Load

A

74.5

77

B

69

70.5

C

73

74

D

71

72.5

Average

72

74

Position 50% Load 100% Load

A

66

67

B

64.5

65.5

C

65.5

67

D

65

66

Average

65

66

10 Feet (3m)

23 Feet (7m)

Summary of Contents for PM4025

Page 1: ...t Motor Starting Tropicallized Windings Weather Enclosure 16 Gauge Steel Enclosure With Sound Material Installed Powder Painted Almond Color Finish Lockable keyed alike Doors With Sound Baffles Vertical Air Discharge For Optimal Sound Control Critical Grade Muffler Integral To Enclosure No Exterior Fasteners Fuel System Operates On Liquefied Petroleum Gas Or Natural Gas Simple Field Conversion Bet...

Page 2: ...ystem Capacity 2 8 Gallons Coolant Flow Rate 17 4 GPM Coolant Heater 120v 500 Watt Thermostatically Controlled Circulation Type Electrical Starting Voltage 12v negative ground Battery Size Required BCI Group 26 Battery Rack 2 0 Cables Included Cranking Current 550cca 0 F Battery Charging Alternator 90 amps Battery Charger 120v AC Bulk 6A 12vdc Absorption 5 5A Taper To 1 5A Between 13 14 4vdc Float...

Page 3: ...0 CFM Total Airflow 4550 CFM Heat Rejected To Coolant 70000 BTU HR Heat Rejected To Exhaust 195000 BTU HR Maximum Exhaust Flow 206 CFM Maximum Exhaust Backpressure 1 1 PSI Exhaust Temperature 1200 F Sound Data 66 66 66 66 dB A Average 23 7m Full Load dB A Average 23 7m Full Load dB A Average 23 7m Full Load dB A Average 23 7m Full Load 2002 Coleman Powermate Inc Coleman is a registered trademark o...

Page 4: ...erature Protection Engine Oil Pressure Monitoring Engine Oil Pressure Protection Overspeed Protection Overcrank Protection Emergency Stop Input Engine Cooldown Watt Metering VA Metering Engine RPM Metering Power Factor Metering Watt hour Metering Engine Run Time Metering Battery Voltage Metering Battery Condition Monitoring Maintenance Interval Timer On Off Auto Selector Switch Low Coolant Level D...