background image

English

Customer Hotline 1-800-445-1805

3

SAFETY AND OPERATION RULES

WARNING indicates a 

potentially hazardous situation

which, if not avoided, could

result in death or serious injury.  

CAUTION indicates a potentially

hazardous situation which, if not

avoided, may result in minor or 

moderate personal injury, or 

property damage. 

WARNING - Failure to follow these instructions
and warnings may result in death, personal
injury, or property damage.

1. Read carefully and understand operator manual 

prior to operation of this product.  Follow all 
warnings and instructions.

2. Know your equipment.  Consider the applications, 

limitations, and the potential hazards specific to 
your unit.

3. Equipment must be placed on a firm, supporting 

surface.

4. Load must be kept within rating stated on 

generator nameplate.  Overloading will damage 
the unit or shorten its life.

5. Engine must not be run at excessive speeds. 

Operating an engine at excessive speeds increases 
the hazard of personal injury.

Do not tamper with parts which may increase 
or decrease the governed speed.

6. To prevent accidental starting, always remove the 

spark plug or cable from the spark plug before 
maintaining the generator or engine.

7. Units with broken or missing parts, or without 

protective housing or covers, should never be 
operated.  Contact your service center for 
replacement parts.

8. Units should not be operated or stored in wet or 

damp conditions or on highly conductive 
locations such as metal decking and steel work.

9.  Keep the generator clean and free of oil, mud and 

other foreign matter.

10.Extension cords, power cords, and all electrical 

equipment must be in good condition. Never 
operate electrical equipment with damaged or 
defective cords.

11. Store the generator in a well ventilated area with 

the fuel tank empty. Fuel should not be stored near 
the generator.

12.Your generator should never be operated under 

these conditions:
a. Uncontrolled change in engine speed. 
b. Electrical output loss.
c. Overheating in connected equipment.
d. Sparking.
e. Damaged receptacles.
f. Engine misfire.
g. Excessive vibration.
h. Flame or smoke.
i. Enclosed compartment.
j. Rain or inclement weather.  Do not let the unit 

get wet when operating.

13.Check the fuel system periodically for leaks or 

signs of deterioration such as chafed or spongy 
hose, loose or missing clamps, or damaged tank or 
cap. All defects should be corrected before 
operation.

14.The generator should be operated, serviced, and 

refueled only under the following conditions:

a. Start and run the generator outdoors.  Do 

not run the generator in an enclosed area, 
even if doors or windows are open; avoid 
areas where vapors may be trapped, such as 
pits, garages, cellars, excavations and boat 
bilges.  DANGER - CARBON MONOXIDE 
HAZARD: The engine exhaust contains 
carbon monoxide, a poisonous, odorless, 
invisible gas which, if breathed, may cause 
death or serious personal injury.  If you start 
to feel sick, dizzy or weak while using the 
generator, shut it off and get to fresh air 
right away; you may have carbon monoxide 
poisoning.

b.Good ventilation for cooling.  Air flow and 

temperatures are important for air cooled 
units.  Temperatures should not exceed 104º F
ambient (40º C).

c. Refuel the generator in a well lighted area. 

Avoid fuel spills and never refuel while the 
generator is running.  Allow engine to cool for 
two minutes prior to refueling.

DANGER indicates a potentially

hazardous situation which, if not
avoided, WILL result in death or

serious injury.  

Summary of Contents for PM0105000

Page 1: ...nual Manuel de l op rateur Manual del operador Record the serial numbers as indicated on your Generator s nameplate Serial No ____________________________ Enregistrer le num ro de s rie figurant sur l...

Page 2: ...iodique 21 Entretien 21 La bougie d allumage 21 Le type d huile 21 Remplacement d huile 21 Nettoyage du filtre air 21 Nettoyage du filtre du robinet essence 21 Nettoyage de la cr pine du r servoir car...

Page 3: ...n good condition Never operate electrical equipment with damaged or defective cords 11 Store the generator in a well ventilated area with the fuel tank empty Fuel should not be stored near the generat...

Page 4: ...D WITH A SPARK ARRESTING MUFFLER If the product will be used around flammable materials such as agricultural crops forests brush grass or other similar items then an approved spark arrester should be...

Page 5: ...bustible Engines 3 Agricultural Wiring handbook of Farm Standby Electric Power 5 English Customer Hotline 1 800 445 1805 OPERATING VOLTAGE CAUTION Operating voltage and frequency requirement of all el...

Page 6: ...ening of the oil fill LOW OIL SENSOR The unit is equipped with a low oil sensor If the oil level becomes lower than required the sensor will activate a warning device or stop the engine If generator s...

Page 7: ...Circuit Breaker The receptacles are protected by an AC circuit breaker If the generator is overloaded or an external short circuit occurs the circuit breaker will trip If this occurs disconnect all e...

Page 8: ...the alternator side of the generator place the foot bracket under the carrier channel Thread a M8 x 15 screw item 115 through the mounting holes and thread a M8 nut item 111 to the bolt to secure the...

Page 9: ...ped 5 Close the fuel shut off valve if the engine is to be put in storage or transported 6 If a cover is used do not install until unit has cooled STARTING THE UNIT Gasoline is very dangerous Serious...

Page 10: ...and gently squeeze out any excess oil 4 Replace the filter element and air filter cover 5 Be sure the filter cover seals properly all around FUEL VALVE FILTER CLEANING 1 Remove the cup at the bottom...

Page 11: ...en 5 Check all generator parts for integrity 6 Clean the Carburetor INFREQUENT SERVICE If the unit is used infrequently difficult starting may result to eliminate hard starting run the generator at le...

Page 12: ...HP 4000 rpm Starting System Recoil electronic ignition Driving System Direct coupling tapered crank Oil Capacity 37 oz 1 1 L Spark Plug Champion RN14YC or equivalent Governor Mechanical adjustable Co...

Page 13: ...ne Damages caused by abuse or accident and the effects of corrosion erosion and normal wear and tear Warranty is voided if the customer fails to install maintain and operate the product in accordance...

Page 14: ...pareil lectrique doivent tre en bon tat Ne jamais faire fonctionner un appareil lectrique dont le cordon d alimentation est ab m ou d fectueux 11 Rangez le nettoyeur haute pression dans un endroit bie...

Page 15: ...21 Avant de transporter la g n ratrice dans un v hicule le vider de tout carburant afin d emp cher les fuites 22 Pour transporter l appareil d un site l autre utilisez les bonnes techniques de levage...

Page 16: ...isation des moteurs fixes combustible 3 Manuel de c blage du r seau d alimentation de secours des appareils agricoles 16 Fran ais V RIFIER LA TENSION ATTENTION V rifier la tension et la fr quence requ...

Page 17: ...au limite le d tecteur activera un appareil qui avertit ou arr te le moteur Si le groupe lectrog ne s arr te mais qu il y a suffisamment d huile v rifier s il se trouve sur un plan inclin entra nant l...

Page 18: ...que D Disjoncteurs Les prises sont prot g es par un disjoncteur alternatif En cas de surcharge ou de court circuit ext rieur le disjoncteur saute Si cela se produit d brancher tout appareil reli au gr...

Page 19: ...e mettre en place le support de pied sous le profil en U Visser un vis de M8 x 15 article 115 dans les trous de fixation puis visser sur le vis un crou M8 article 111 pour fixer le support de pied au...

Page 20: ...phonique 1 800 445 1805 L essence est un produit tr s dangereux Un incendie r sultant du contact de l essence avec des surfaces chaudes peut causer de graves blessures ou entra ner la mort 1 Ne pas me...

Page 21: ...t et le couvercle du filtre air en place 5 S assurer de la parfaite tanch it du pourtour du couvercle du filtre NETTOYAGE DU FILTRE DU ROBINET ESSENCE 1 Retirer la coupelle du bas du robinet essence a...

Page 22: ...t essence soit ouvert 5 V rifier les pi ces du groupe lectrog ne afin de vous assurer de leur int grit 6 Nettoyer le carburateur USAGE PEU FR QUENT Si la g n ratrice est rarement utilis e il est possi...

Page 23: ...e de propulsion Accouplement direct bilegrequin effil Capacit d huile 1 1 litres 37 oz Bougie Champion RN14YC ou l quivalent R gulation M canique ajustable Syst me de refroidissement Refroidissement a...

Page 24: ...osion de l rosion ainsi que de l usure normale La garantie est annul e si le client n arrive pas installer garder et faire fonctionner le produit conform ment aux directives et aux recommandations de...

Page 25: ...generador 12 Su generador no deber operarse jam s si ocurre do lo siguiente a Cambio fuera de control en la velocidad del motor b P rdida de carga el ctrica c Sobrecalentamiento del equipo conectado d...

Page 26: ...se lesiones personales 23 Para evitar quemaduras no toque el silenciador del motor u otras superficies del generador que se hayan calentado durante la operaci n PUEDE SER QUE SU PRODUCTO NO ESTE EQUIP...

Page 27: ...ci n auxiliar para granjas 27 Espa ol PRECAUCION El requerimiento de voltaje y frecuencia operativa de todos los equipos electr nicos debe comprobarse antes de enchufarlos a este generador Pueden ocur...

Page 28: ...r que el requerido el sensor activar un artefacto de la advertencia o parar el motor Si se apaga el generador y el nivel de aceite se encuentra dentro de las especificaciones verifique que el generado...

Page 29: ...extra da no debe exceder los valores nominales de la placa de identificaci n D Interruptor Los recept culos se protegen mediante un cortacircuitos de CA Si se sobrecarga el generador u ocurre un cort...

Page 30: ...de la pie bajo el canal portador Enrosque un tornillo de M8 x 15 art culo 115 a trav s de los orificios de montaje y enrosque una tuerca M8 art culo 111 al perno para asegurar el soporte de la pie al...

Page 31: ...l ctrico 4 No abandone el generador hasta que se haya detenido por completo L nea Directa 1 800 445 1805 ARRANQUE DEL UNIDAD La gasolina es muy peligrosa Si la gasolina hace contacto con superficies c...

Page 32: ...ltro y la cubierta del filtro de aire 5 Aseg rese de que la cubierta del filtro selle adecuadamente en todas partes C MO LIMPIAR EL FILTRO DE LA V LVULA DE COMBUSTIBLE 1 Retire la copa en la parte inf...

Page 33: ...vula de combustible 5 Verifique la integridad de todas las piezas del generador 6 Limpie el carburador SERVICIO POCO FRECUENTE Si la unidad no se utiliza frecuentemente podr an ocurrir dificultades al...

Page 34: ...stema de conducci n Conexi n directa manivela ahusada Capacidad de aceite 1 1 litros 37 oz Buj a Champion RN14YC o equivalente Gobernador Mec nico adjustable Sistema de enfriamiento Enfriamiento forza...

Page 35: ...el desgaste y el uso normales La garant a no ser v lida si el consumidor no instala da mantenimiento y hace funcionar el producto de acuerdo con las instrucciones y recomendaciones de la Compa a desc...

Page 36: ...36 Customer Hotline 1 800 445 1805 PARTS DRAWING SCHEMA DES PI CES DIAGRAMA DE PIEZAS Model PM0105000...

Page 37: ...Screw M8 x 1 25 40 Vis Tornillo 2 34 0064352 Connecting rod cap Capuchon connectant de tringle Tapa de biela 1 35 0064353 Bearing 6207 Roulement Cojinete 1 36 0064354 Connecting rod body Corps connect...

Page 38: ...566 Absorber tank Absorbeur Absorbente 4 104 0065304 Panel wired Tableau complet c bl Panel cabeado completo 1 105 0064576 Isolator Sectionneur Aislador 4 106 0064577 Nut M10 x 1 5 crous Tuerca 8 107...

Page 39: ...tricista matriculado o representatnte de servicio autorizado Bajo ninguna circunstancia debe permitirse que una persona que no est capacitad trate de manipular cables dentro del circuito de servicio e...

Page 40: ...material respects to the part as described in the engine manufacturer s application for certification The ECS Warranty only pertains to emissions related parts on your engine as follows 1 Any warrante...