13 HP Honda OHV engine

*

Cast-iron cylinder sleeves

*

Low oil sensor

*

Receptacles on control panel

*

Voltmeter and hour meter on panel 

*

Idle control

*

Automatic voltage regulator (AVR)

*

Battery charger

*

CordKeeper™

*

5.6 gallon metal fuel tank

*

Spark arrester 

*

Portability Kit

A.

120/240 V, 30 Ampere Twistlock Receptacle

A maximum of 30 amps may be drawn from the 120/240 

volt receptacle, provided it is the only receptacle used. 
However, current must be limited to the nameplate rating.  If the
120/240 volt receptacle is used along with the 120 volt
receptacle, the total load drawn must not exceed the nameplate
ratings.

B.

Idle Control Switch

Some models are equipped with an idle control switch. 

(See Idle Control).

C.

Circuit Breakers

The receptacles are protected by an AC circuit breaker.  If

the generator is overloaded or an external short circuit occurs,
the circuit breaker will trip.  If this occurs, disconnect all
electrical loads and try to determine the cause of the problem
before attempting to use the generator again. If overloading
causes the circuit breaker to trip, reduce the load. 

NOTE:

Continuous tripping of the circuit breaker may cause
damage to generator or equipment.  

The circuit breaker may

be reset by pushing the button of the breaker.

D.

Hour Meter

An hour meter is provided to keep track of run time of the

unit.  This may be used to track maintenance schedules.

E.

Voltmeter

Provides visual indication of generator output voltage from 

0-300 volts.

F.

120 Volt GFCI Receptacle

Ground Fault Circuit Interrupter duplex receptacle is rated

so that a total of 20 amps may be drawn regardless of whether
both halves or just one receptacle is used.  This receptacle may
be used along with th other receptacles provided the generator
is not overloaded and total power drawn is kept within
nameplate ratings.

Ground Fault Circuit Interrupter

(Conforms to U.L 943, Class A and NEC requirements)
This device protects you against hazardous electrical shock
that may be caused if your body becomes a both through which
electricity travels to reach ground.  This could happen when
you touch an appliance or cord that is “ live “ through faulty
mechanism, damp or worn insulation, etc.

G. 120 V, 30 Ampere Twistlock Receptacle

You may draw a maximum of 30 amps or 3600 watts from

this receptacle.  If other receptacles are used at the same time,
total power used must be kept within nameplate ratings.

H.

CordKeeper™

The CordKeeper™ is a unique

feature used to prevent plugs from
being pulled out of the 120-volt
receptacles.

I.

Battery Charger
NOT RECOMMENDED FOR USE WITH GEL PACK,

SEALED OR SMALL (MOTORCYCLE) BATTERIES.

These generators contain an additional circuit used for

battery charging purposes.  A double binding post is provided
on the control panel.  The battery charger on this generator is
referred to as an unregulated taper charger - the most widely
used in the market today.  The amount of current flowing will
depend on the charging voltage and battery's state of charge.
As the on-charge output current to the battery decreases, the
output current to the battery increases and nearly becomes
constant.  Taper chargers are intended to be used with the
provision that they will be disconnected from the battery after a
maximum time on charge.  Normally a period of 30 to 120
minutes is sufficient to recharge a weak battery.  The charge
level of the battery should be checked periodically. 

CAUTION:  This battery charging system is 
intended to recharge weak batteries, not to 
"boost start" vehicles.  Do not overcharge 
battery or leave battery unattended.

Note: 

When the battery charger circuit is in use, the AC

capacity is reduced by 180 watts.  Make sure the combined
load is within the rated limits.

Before charging a storage battery, check the electrolyte

fluid level in all the cells.  Add distilled water to each cell, if
necessary, to bring the level back up to the manufacturer's
required level.

WARNING:  Storage batteries give off 

EXPLOSIVE hydrogen gas while charging. 
Do not allow smoking, open flames,sparks,
or spark producing equipment in the area 
while charging.

2

English

CONTROL PANEL

MAJOR GENERATOR FEATURES

Summary of Contents for PL0496504.17

Page 1: ...nstructions provided prior to operation IMPORTANT Prière de vous assurer que les personnes destinées à utiliser cet appareil ont pris soin d en lire et d en comprendre le mode d emploi ou les directives avant de le mettre en marche IMPORTANTE Asegúrese que las personas que utilizarán este equipo lean y entiendan completamente estas instrucciones y cualquier instrucción adicional proporcionada ante...

Page 2: ...ck that may be caused if your body becomes a both through which electricity travels to reach ground This could happen when you touch an appliance or cord that is live through faulty mechanism damp or worn insulation etc G 120 V 30 Ampere Twistlock Receptacle You may draw a maximum of 30 amps or 3600 watts from this receptacle If other receptacles are used at the same time total power used must be ...

Page 3: ...esigned to extend engine life and improve fuel usage by slowing the engine down to approximately 2000 RPM in a No Load condition The noise is also greatly reduced during this condition When power is required from the generator an electronic control module automatically senses current flow in the electrical outlet and allows the engine to return to full speed or standard operating condition Likewis...

Page 4: ...ed States or Canada Any other expense including consequential damages incidental damages or incidental expenses including damage to property Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you IMPLIED WARRANTIES Any implied warranties including the Implied Warranties of Merchantability and Fitness For...

Page 5: ...rcuit en cas de fuite à la terre conforme à U L 943 Catégorie A et ixigences NEC Cet appareil vous protège contre les dangers de chocs électriques qui peuvent ítre causés si votre corps devient un conduit pour l électricité se rendant à la terre Ceci peut se produire si vous touchez u appareil ou un cordon qui est sous tension suite à un mécanisme défectueux un isolant usé ou humide etc G Prise à ...

Page 6: ... de vie utile du moteur et en améliorer la consommation de carburant en réduisant le régime à environ 2000 tours mn en condition sans charge Ceci assure également une forte réduction du bruit Lorsque la production d électricité doit reprendre un module de commande électronique sent le débit de courant dans la prise de courant et permet au moteur de retourner à son plein régime ou aux conditions de...

Page 7: ...tres frais y compris ceux dûs à des dommages indirects ou accidentels ni les dépenses imprévues y compris les dommages matériels Certaines provinces ne permettent pas l exclusion ou la limitation des dommages indirects ou accidentels et les limitations ou exclusions ci dessus peuvent ne pas s appliquer à votre cas GARANTIES IMPLICITES Toutes garanties implicites y compris les Garanties implicites ...

Page 8: ...y NEC Este dispositivo lo protege contra una sacudida eléctrica peligrosa que puede causarse cuando su cuerpo se convierte en una senda por la cual la electricidad viaja para alcanzar la tierra Esto puede ocurrir cuando usted G Receptáculo de cierre giratorio de 120 voltios Puede extraerse un máximo de 30 amp o 3600 vatios desde este receptáculo Si se utilizan otros receptáculos al mismo tiempo la...

Page 9: ...ontrol electrónico automático detecta el flujo de corriente en el tomacorriente eléctrico y permite que el motor vuelva a plena velocidad o a condiciones de funcionamiento estándar Del mismo modo cuando se retira la carga el generador automáticamente regresará a la condición de marcha en vacío después de un retardo de 4 a 5 segundos Se monta un práctico interruptor en el panel de control para logr...

Page 10: ... Estados Unidos Canadá y México Cualquier otro gasto incluyendo daños emergentes daños o gastos incidentales incluyendo daños a la propiedad Algunos estados no permiten la exclusión o limitación de daños incidentales o emergentes de modo que la limitación o exclusión anterior podría no ser aplicable en su caso particular GARANTIAS IMPLICITAS Cualquier garantía implícita incluyendo las Garantías Im...

Page 11: ...11 PARTS DRAWING DES PIÈCES REPUESTOS ...

Page 12: ...ionneur Conjunto de soporte 1 21 0056039 Bracket stator Sectionneur stator Conjunto de soporte 1 22 0049279 Bolt wz 5 16 18 x 1 2 Boulon Perno 3 23 0048736 Nut nyloc 5 16 18 Écrous nyloc 5 16 18 Tuerca nyloc 5 16 18 5 25 Note B Washer flat 5 16 Rondelles plates 5 16 Arandela plana 5 16 5 26 Note B Bolt 5 16 18 x 1 1 2 Boulon Perno 2 28 0049224 Assembly ground wire Ens fil de masse tressé Conjunto ...

Page 13: ...our éviter toute blessure personnelle ou dommage à l équipement l installation et tout entretien devralent être effectués par un électricien qualifié ou un préposé au service autorisé En aucun cas une personne non qualifiée ne devrait essayer de faire le raccord au circuit principal Électricité La charge limite en ampères des fils de phase allant des bornes de la génératrice au premier appareil en...

Page 14: ...NOTES REMARQUES NOTAS 14 ...

Page 15: ...NOTES REMARQUES NOTAS 15 ...

Page 16: ...4970 Airport Road P O Box 6001 Kearney NE 68848 1 800 445 1805 1 308 237 2181 Fax 1 308 234 4187 ...

Reviews: