background image

Owner’s Manual for Portable Generator

1

Section 1 Introduction and Safety

Introduction

Thank you for purchasing a Powermate prod-

uct. This unit has been designed to provide

high-performance, efficient operation, and

years of use when maintained properly. 

If any section of the manual is not understood,

contact your nearest Independent Authorized

Service Dealer (IASD), or contact Powermate

Customer Service at 1-800-445-1805, or

www.powermate.com with any questions or

concerns.
The owner is responsible for proper mainte-

nance and safe use of the equipment. Before

operating, servicing or storing this generator:
• Study all warnings in this manual and on

the product carefully.

• Become familiar with this manual and the

unit before use.

• Refer to the Assembly section of the man-

ual for instructions on final assembly proce-

dures. Follow the instructions completely.

Save these instructions for future reference.

ALWAYS supply this manual to any individual

that will use this machine.
THE INFORMATION CONTAINED HEREIN

WAS BASED ON MACHINES IN PRODUC-

TION AT THE TIME OF PUBLICATION.

POWERMATE RESERVES THE RIGHT TO

MODIFY THIS MANUAL AT ANY TIME.

Safety Rules

The manufacturer cannot anticipate every

possible circumstance that might involve a

hazard. The warnings in this manual, and on

tags and decals affixed to the unit are, there-

fore, not all inclusive. If using a procedure,

work method or operating technique that the

manufacturer does not specifically recom-

mend, verify that it is safe for others. Also

make sure the procedure, work method or

operating technique utilized does not render

the equipment unsafe.
Throughout this publication, and on tags and

decals affixed to the generator, DANGER,

WARNING, CAUTION and NOTE blocks are

used to alert personnel to special instructions

about a particular operation that may be haz-

ardous if performed incorrectly or carelessly.

Observe them carefully. Their definitions are

as follows:

NOTE: 

Notes contain additional information

important to a procedure and will be found

within the regular text of this manual.
These safety warnings cannot eliminate the

hazards that they indicate. Common sense

and strict compliance with the special instruc-

tions while performing the action or service

are essential to preventing accidents.

Safety Symbols and Meanings

• If you start to feel sick, dizzy, or weak after

the generator has been running, move to

fresh air IMMEDIATELY. See a doctor, as

you could have carbon monoxide poison-

ing.

(000100a)

WARNING

Consult Manual. Read and understand manual
completely before using product. Failure to 
completely understand manual and product
could result in death or serious injury.

(000001)

DANGER

Indicates a hazardous situation which, if not avoided, 
will result in death or serious injury.

(000002)

WARNING

Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.

(000003)

CAUTION

Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.

000657

DANGER

Using a generator indoors CAN KILL YOU IN MINUTES.

 

Generator exhaust contains carbon monoxide. This is 
a poison you cannot see or smell.

NEVER use inside a home 
or garage, EVEN IF doors 
and windows are open.

Only use OUTSIDE and 
far away from windows, 
doors, and vents.

(000103)

DANGER

Asphyxiation. Running engines produce carbon 
monoxide, a colorless, odorless, poisonous gas. 
Carbon monoxide, if not avoided, 
will result in death or serious injury.

Summary of Contents for CX1400

Page 1: ...intended to be used in a critical life support application Failure to adhere to this warning could result in death or serious injury MODEL ________________________ SERIAL ________________________ DATE...

Page 2: ...ator Limits 12 Transporting Tipping of the Unit 12 Starting Pull Start Engines 13 Generator Shut Down 13 Low Oil Level Shutdown System 13 Section 4 Maintenance and Troubleshooting 14 Maintenance 14 Ma...

Page 3: ...ughout this publication and on tags and decals affixed to the generator DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation that may...

Page 4: ...hair and appendages away from moving parts Failure to do so could result in death or serious injury 000108 WARNING Hot Surfaces When operting machine do not touch hot surfaces Keep machine away from c...

Page 5: ...the Authority Having Jurisdiction AHJ for any local codes or standards which may be appli cable to your jurisdiction 000144 DANGER Electrocution Contact with bare wires terminals and connections while...

Page 6: ...lt AC 30 Amp Locking Receptacle NEMA L14 30R 3 Circuit Breakers AC 4 On Off Switch 5 Hour Meter 6 Ground Terminal 7 Choke Lever 8 Fuel Tank 9 Oil Drain 10 Oil Fill 11 Air Cleaner 12 Recoil Handle 13 F...

Page 7: ...W 4375W 6875W Rated AC Voltage 120 120 120 240 Rated AC Load Amps 11 7 29 2 45 8 22 9 Rated Frequency 60 Hz 3600 RPM 60 Hz 3600 RPM 60 Hz 3600 RPM Phase Single Phase Single Phase Single Phase Unit Wei...

Page 8: ...TEST and RESET button NOTE Limit length of extension cords to fif teen feet or less to prevent voltage drop and overheating of wires Figure 2 6 120 VAC 20 Amp GFCI Duplex Receptacle NEMA 5 20R 120 VAC...

Page 9: ...y Call Powermate Customer Service at 1 800 445 1805 for any assembly issues or con cerns Please have model and serial number available The following tools are required to install the accessory kit See...

Page 10: ...65 bolt 8 Figure 2 10 Wheel and Foot Assembly CX3500 CX5500 See Figure 2 11 Install wheels as follows 1 Slide axle pin 3 through wheel 1 M12 x 4mm flat washer 7 and frame 2 Install M12 x 4mm flat was...

Page 11: ...ak in before using synthetic oil NOTE Some units have more than one oil fill location It is only necessary to use one oil fill point 5 Thread dipstick into oil filler neck Oil level is checked with di...

Page 12: ...tant to pre vent gum deposits from forming in fuel system parts such as the carburetor fuel hose or tank during storage Alcohol blended fuels called gasohol ethanol or methanol can attract moisture wh...

Page 13: ...the generator is used at a construction site there may be additional regulations which must be observed Connecting the Generator to a Building Electrical System When connecting directly to a building...

Page 14: ...r wattage requirements Table 3 Wattage Reference Guide Transporting Tipping of the Unit Do not operate store or transport the unit at an angle greater than 15 degrees Device Running Watts Air Conditio...

Page 15: ...ens and electrical output to that receptacle is lost Read Know Generator Limits carefully Generator Shut Down 1 Shut off all loads and unplug electrical loads from generator panel receptacles 2 Let en...

Page 16: ...ed NOTE DO NOT use a garden hose to clean generator Water can enter engine fuel system and cause problems If water enters generator through cooling air slots some water will be retained in voids and c...

Page 17: ...n area around oil fill and oil drain plug 4 Remove oil fill cap 5 Remove oil drain plug and drain oil com pletely into a suitable container 6 Install oil drain plug and tighten securely 7 Slowly pour...

Page 18: ...from muffler outlet tube 3 Remove screen D and replace if torn perforated or otherwise damaged If screen is not damaged clean with com mercial solvent 4 Replace screen and retainer secure with screw 5...

Page 19: ...ot been treated with fuel stabilizer it must be drained into an approved container Run engine until it stops from lack of fuel Use of fuel stabilizer in fuel storage container is recommended to keep f...

Page 20: ...k plug wire not connected to spark plug 7 Bad spark plug 8 Water in fuel 9 Overchoking 10 Low oil level 11 Excessive rich fuel mixture 12 Intake valve stuck open or closed 13 Engine lost compression 1...

Page 21: ...Owner s Manual for Portable Generator 19 Notes...

Page 22: ...20 Owner s Manual for Portable Generator...

Page 23: ......

Page 24: ...ermate All rights reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Powermate Powermate LLC S45 W29290 Hwy 59 Waukesha...

Reviews: