background image

9. Clean and re-install the O-Type SEAL (11) and the Dip Stick (10). Do not damage the threads of 

the aluminum Oil Cylinder Cover when re-installing.

     

Reminder!

Dispose used dirty oil properly. Take it to a waste oil-recycling center. Do not dump it in the sewer 

or on the ground or mix in with the trash.

Recommended hydraulic oil

The following are the recommended hydraulic oil brands 

to be used for the hydraulic ram of the Log Splitter:

1. SHELL TELLUS T22

2. ARAL VITAM Gf22

3. P ENGERGOL HCP22

4. MOBIL  DTE11

(Do not use other brands of hydraulic oil)

Trouble-shooting

Here are the most common problems that may occur when using the log splitter and their cor-

responding recommended solutions. In case there are problems that cannot be resolved please 

contact your dealer. Have an authorized professional check and carry out maintenance and 

repairs if needed. If the Log Splitter has been operated on by any unauthorized personnel, the 

guarantee for the Log Splitter will automatically be null and void and the manufacturer will be 

relieved of any responsibility for any injury to persons and animals and any damage to property.

9

Summary of Contents for XM-580

Page 1: ......

Page 2: ...ave them checked by an authorized professional if needed You must make sure to have defective or damaged parts replaced and have the Log Splitter repaired if it is not operating properly before actual use and operation 3 Before doing any inspection calibration or other maintenance work on the Log Splitter make sure that the Log Splitter is unplugged Do this even when simply changing spare parts su...

Page 3: ... eye protection gear when operating the Log Splitter 2 Never operate the Log Splitter while under the influence of drugs alcohol and certain medication 3 Never stay on top of the Log Splitter You risk bodily injury if you fall 4 Clean up as you work accumulated split wood and wood chips can create a hazardous work environment 5 Always check the Log Splitter for lodged splinters to avoid possible p...

Page 4: ...ge the Log Splitter such as nails screws and wires before splitting Remove all branches from the logs before splitting The log end surface must be level when placed on the Log Splitter Always split logs along the direction of vein Do not put logs vertically on the Log Splitter This may damage the Log Splitter Always use both hands to handle the control device Do not use other means to oper ate the...

Page 5: ...eference What is more important is the hardness of the log and the Log Splitters capability to split it Hard logs with knots may be too difficult for the Log Splitter to split UNPACKING AND CHECKING BEFORE INSTALLATION Before installing and using the Log Splitter remove all the components from the packaging and check if they are complete and in good condition Sort and check all the components for ...

Page 6: ...use 6 OPERATING PROCEDURE 1 Prepare Work Area Make it safe and efficient by planning the work before you begin Position your logs for splitting within easy access Prepare an area where you will place the split logs also within easy reach If they will be loaded into a receptacle or on a truck position as near as possible 2 Prepare Logs for Splitting Sort out your logs before you start splitting Sep...

Page 7: ... at an angle Make sure that one end of the log is squarely in contact with the Wedge J in Figure 1 and the other end with the Log Pusher B in Figure 1 7 Start Splitting Logs Press down on the Electric Motor Start Switch F in Figure 1 with one hand The motor will start to spin Wait a few seconds until the motor spins fast enough to create the necessary pressure in the Hydraulic pump When there is e...

Page 8: ...ards the bottom the Log Pusher moves slower but with maximum power MAINTAINING THE LOG SPLITTER Warning Be sure to unplug the power cord before doing any maintenance work Sharpening the Wedge There is usually no need to sharpen the wedge until after long periods of operation When it is required use a fine toothed file to sharpen the Wedge Carefully remove any flat spots or burrs on the edge Changi...

Page 9: ...ITAM Gf22 3 P ENGERGOL HCP22 4 MOBIL DTE11 Do not use other brands of hydraulic oil Trouble shooting Here are the most common problems that may occur when using the log splitter and their cor responding recommended solutions In case there are problems that cannot be resolved please contact your dealer Have an authorized professional check and carry out maintenance and repairs if needed If the Log ...

Page 10: ...here is air in the circuit Leakage from the tank Seals worn Corrective action Re position the log Make sure it is not at an angle Stop the Log Splitter then turn the log 90 degrees then try split ting the log again Try to cut a small part or use other means to reduce the size of the log Sharpen the wedge check for burrs or nicks file if necessary Locate the leak using a piece of card or wood Conta...

Page 11: ...Parts Diagram 11 ...

Page 12: ... Spring O ring oil seal Piston O ring oil seal Square piston ring Oil cylinder casing Dip stick O ring oil seal Teflon seal ring O ring oil seal Bleed screw M3x10 Oil cylinder cover Screw stud Philips screw M6x20 Carrying handle Supporting foot Nut M6 Screw M6x14 Rubber supporter for electrical motor Switch dust shield Switch Switch seat Nut M8 Fixing washer Capacitor Dustproof rubber sealing ring...

Page 13: ...O ring oil seal Screw 8 mm Nut M8 Oil pump cover Electrical motor assembly Screw M8x30 Log guiding plate Main Body Plastic sheath plate Log pusher assembly O ring oil seal Oil cylinder cover front Spring Fixing screw M8x30 Handle seat Valve knob Handle bar Handle Nut M8 Brass shim Wheel axle cover Shaft fixation hook Rubber wheel Wheel frame Support plate Washer 10 mm Spring Protection hood 13 ...

Page 14: ...es and face from chips and splinters which may be generated during opera tion Do not remove or tamper with the protection and safety devices on the Log Splitter Only the person operating the Log Splitter should be within 5 meters of the Log Splitter when in use No other person or animal may be present within the 5 meter radius Any used oil for disposal from the Log Splitter must not be dumped into...

Page 15: ...ng or other acts of nature b Unauthorized modification of unit c External sources such as power fluctuation and weather d Repair or attempted repair and alteration by unauthorized parties e Any damage to product due to shipment f Removal or installation of product g Use of parts and supplies other than those produced or recommended by Powerhouse Log Splitters Removal installation and set up servic...

Page 16: ......

Reviews: