Operation
38
3.
Turn the Engine OFF/ON/CHOKE control to “OFF” 2.
a)
Ignition circuit is switched off.
b)
Fuel is switch off.
7.
AC Parallel Operation
AC parallel operation allows the connection between two generators to increase available power.
Before connecting an appliance to the 50A receptacle on the parallel kit, you must:
o
Make sure that the appliance is in good working order.
o
Verify the appliance electrical rating does not exceed that of the receptacle.
o
Ensure that each generator is individually grounded. See Installation/Initial Set-up section.
o
Ensure that the ESC switch is in the same position on both generators.
o
Make sure all devices that were connected to the generator’s outlets have been disconnected.
Note: Most motorized appliances require more than their electrical rating for startup. When an
electrical motor is started, the overload indicator (red light) may come on. This is normal if the
overload indicator (red light) goes off within 4 seconds. If the overload indicator (red light) stays
on, contact Powerhorse Product Support @ 1-866-443-2576.
Use parallel kit
Item # 51122 to connect
Item # 42411 (2 KW)
+
Item # 792220 (3 KW)
Use parallel kit
Item # 51123 to connect
Item # 792220 (3 KW)
+
Item # 792220 (3 KW)