FINAL PHASE
In this phase the current and the tension are controlled: the maximum current is equal
to Imin, and the tension rises until the absorbed current falls.
This phase is visualised by the flashing of the LED MAN, and by the C1, C2, C3 Led
bar that works as a decreasing ammeter.
Achieved and maintained for 2 seconds the tension of 16 V (pb) 15,25V (gel) at the
battery terminals, the charge cycle TERMINATES, emitting a BEEP of 1 second,
returning to the initial settings, set-up by SET.
THE BATTERY CHARGER IS READY FOR ANOTHER RECHARGE
.
TIMEOUTS OF THE CHARGE PHASES.
TIMEOUT
1
2
3
4
5
6
7
8
TIMEOUT
FASE BULK
10h45
10h
9h
8h
7h15
6h15
5h30
4h30
TIMEOUT
TOTALE
15h45
15h
14h
13h
12h15
11M5
10h30
9h30
- Before charging the unit, read the instruction manual carefully;
ATTENTION :
- Check the input voltage and adapt the regulation on the power transformer
- For indoor use only - do not expose the unit to the rain or similar elements
POWERGEN s.r.l.