1. INSTALLATION
q
The installation environment shall be capable of ensuring the user’s safety and the
conditions for a correct operation
q
Powergen Processor battery charger is exclusively designed to recharge traction
batteries and each unit is assigned to a specific battery.
q
Powergen Processor battery charger has IP 20 protection degree, therefore it shall be
protected from rain and water sprays. It shall be installed away from easily inflammable
materials and shall not be used as a supporting top. The presence of dust and/or
corrosive environments may damage the components seriously.
q
Do not lay any materials which may obstruct the cooling air flow.
q
The rectifier shall be laid on the floor in horizontal position. For special requirements it
may also be placed on special raised shelves.
ATTENTION :
VIBRATIONS DURING TRANSPORT COULD CAUSE UNPLEASANT
DRAWBACKS, SO BEFORE STARTING UP THE UNIT, PLEASE CHECK NUTS
AND BOLTS FOR TIGHTNESS.
POWERGEN s.r.l.
2. CONNECTION TO THE SINGLE PHASE LINE
q
It is absolutely necessary to plug into a current outlet being proportional to the power
of the installed battery charger (s.the KW value on the rating plate put on the side or
on the rear)
q
Make sure also the EARTH cable has been correctly connected.
q
The unit comes is pre-set for a 230/240 VAC.