ELECTRICAL SAFETY
CAUTION! All wiring should be performed by a qualified electrician.
1. Make certain that power source conforms to requirements of your equipment.
2. Disconnect power source before cleaning or servicing.
3. Protect yourself against electric shocks when working on electrical equipment. Avoid body contact with
grounded surfaces. There is an increased chance of electrical shock if your body is grounded.
4. When wiring an electric driven device or circuit, follow all electrical and safety codes, as well as the most
recent Canadian Electrical Code (CE) and Canadian Centre for Occupational Health and Safety (CCOHS).
TOOL USE AND CARE
This tool was designed for a specific function. Do not modify or alter this tool or use it for an unintended purpose.
PARTS IDENTIFICATION
Carefully remove the parts and accessories from the packaging and inspect for damage. Make sure that all items in
the parts identification are included.
WARNING! Do not operate the tool if any part is missing. Replace the missing part before operating. Failure to
do so could result in a malfunction and serious personal injury.
Contents:
• Control Unit
• Remote Key Fob
• Wiring Harness with 15 amp Fuse
• 4 Channel Output Wires
• Adhesive Hook and Loop Fastener
NOTE:
Control Unit functions as a switch only. You will also need a 12V power source for each connected accessory.
INSTALLATION
NOTE:
You will need wire strippers (not included) to complete the installation.
1. Join the Wiring Harness to the Control Unit.
2. Strip the red and black wires.
3. Connect the red wire to the positive power wire, ideally the accessory power wire from the fuse box.
4. Connect the black wire to a chassis ground.
5. Join the 4 Channel Output Wires to the Control Unit.
6. From a colour matched pair of wires on the 4 Channel Output Wires, strip ends of the wire.
7. Connect one wire to the chassis ground.
8. Connect the other wire to the ground side of the 12V powered accessory.
9. If the load of the 12V powered accessory you wish to connect is above 15 amps, you will need to add a
heavy duty relay (not included) between the accessory and the Control Unit (see diagram below).