5
2
Configurable items
Some settings can be configured using front panel and CAN commands. Almost all settings can be
configured using optional radio module. All settings can be set at the factory.
configuring method
documented in
front panel
chapter "Editing charging configuration"
CAN bus
chapter "CAN remote control"
radio
Micropower Access Service Tool documentation
factory setting
ask from your supplier. Convenient if your order large quantities.
Operation modes are described in chapter "Modes". Other items are listed below.
2.1
Charging parameters
This group of settings includes algorithm, battery capacity, cellcount, cable resistance and base
load. These items are applied only in charger mode. These settings can be set also using CAN bus.
See chapter "CAN remote control".
Algorithm number
configurable via
front panel: yes
CAN: yes
radio: yes
factory setting: yes
Default value: 1
Algorithm number is unique identifier of algorithms within Micropower Access and
Powerfinn Robust series of chargers. See chapter "Algorithms" for available algorithms and
numbers.
Battery capacity
configurable via
front panel: yes
CAN: yes
radio: yes
factory setting: yes
Default value: 50, unit: Ah, range: 50 ... 2000
A list of predefined values between 50 and 800 is available using the front panel. See
chapter "Editing charging configuration". While these are often sufficient, battery capacity
can be set freely using other methods. Accurate capacity setting ensures optimal charging
process.
Number of cells
configurable via
front panel: no
CAN: yes
radio: yes
factory setting: yes
Default value: (according to nominal voltage of the model), unit:-, range: 6 ... 50 ( naturally
meaningful maximum depends on nominal voltage of the model).
Number of cells can be configured to a lower value than the nominal. For example 12 V
battery can be charged using nominally 24 V charger.
Base load