12
4.2
LK10-04 freely ventilated lead-acid, using ionic mixing
Algorithm number: 2
Ionic mixing current pulses are used to reduce charging time without using air pump.
Charging phase "top fill" c8 % compared to charged Ah of main phase.
Battery temperature compensation:
- voltage -3 mV / °C per cell, neutral at 30 °C
- current derated to zero in the range [-30 ... -35] and [+45 ... +60] °C
* In maintenance phase, battery voltage is periodically checked. If it is below 2.17 V/cell, 2 minute
0.05 C current pulse is used.