Powerfinn PAC 600 Installation And User Manual Download Page 3

Installation

The following points must be respected when choosing a location for 
the charger.

1.

The location must be dry, dust-free and indoors. The acceptable 
temperature range for operation is 0°C to +40°C. A higher ambient 
temperature will limit the current supply, see appendix A on page 6. 
Caution: The charger is not waterproof. Keep the charger dry and  
away from areas with high humidity in order to avoid the risk of  
electrical shock and damage to the charger.

2. The   equipment   may   be   installed   horizontally   or   vertically.   The 

horizontal   position,   however,   is   recommended   with   a   height   of   1 
meter above floor level.

3. To ensure sufficient ventilation, leave a free space of at least 10 cm 

around all sides of the charger. Do not cover the unit.

4. The charging process generates explosive hydrogen gas. Keep the 

area   well   ventilated.   Never   use   an   open   flame   and   avoid   sparks 
close to the battery and charger.

5. The   floor   and   material   below   the   charger   must   be   fire-resistant. 

Install the charger using the railed assembly plate (see figure).  With 
vertical mounting, place the vertical slide barrier downwards. Fasten 
the assembly board to the wall using the mounting holes in the back 
of   the   board.   Next,   place   the   charger   in   the   assembly   board   by 
inserting   the   rails   at   the   bottom   side   of   the   charger,   into   the   rail 
guides. Finally, fasten the charger to the assembly board by using 
the   small   screws   on   the   side   of   the   board.   Fix   the   sticker   (see 
appendix C), if provided, to the topside of the charger. Plug the main 
power cord into an earthed mains outlet.

3

Summary of Contents for PAC 600

Page 1: ...PAC 600 PAC 800 PAC 800 comfort Installation and User Manual Advanced Battery Chargers...

Page 2: ...cess The charger is compact lightweight and meets the EU safety and EMC requirements General PAC chargers are available for a variety of battery types The charger type is indicated on the label attach...

Page 3: ...at least 10 cm around all sides of the charger Do not cover the unit 4 The charging process generates explosive hydrogen gas Keep the area well ventilated Never use an open flame and avoid sparks clo...

Page 4: ...ltage charging 5 During the charging process the STATUS LED light is continuously orange A constant red color indicates either too low or too high a voltage or that the battery is not connected to the...

Page 5: ...a with plenty of water for several minutes If visible injury occurs contact a physician immediately In case of eye injuries always contact a physician 4 The charging process generates explosive hydrog...

Page 6: ...e equipment has a guarantee of two years from the date of purchase Guarantee covers manufacturing and component failures and is valid only if the equipment is installed and used according to the instr...

Page 7: ...dix B Example of a front panel label varies per model Appendix C Example of a top label varies per model Note Constant voltage chargers do not have DISCONNECTED and READY markings mentioned on the lab...

Page 8: ...Per miehenkatu 6 24100 Salo tel 358 0 2 777 290 fax 358 0 2 777 2918 info powerfinn fi www powerfinn fi 8...