47
4.4.3 System
Configuration
SNMPv3
System Configuration
SNMPv3
screen allows configuration of three
different SNMPv3 user types and notification (Trap) which requires
same parameters as any other SNMPv3 user.
Figure 4-8: System Configuration SNMPv3 Screen
Guest User – Allows
limited read only access to MIB-II
System OiD tree. It should be used by SNMP managers
who prefer not to expose their real username & password in
order to pool the device for "keep alive" report. Guest user
has no authentication or privacy (encryption) ability.
View User –
Has reading (GET) access to all SNMP
branches but cannot perform any modifications
(SET).
User Name –
SNMPv3 user (mandatory field)
Authentication Password (MD5) –
applicable when
MD5 or MD5+DES is being used.
Privacy Password (DES) –
applicable only when