P A G E   1 3

In Review 

 

Never attempt to operate the E    R    P1500-12 inverter from any power source other 

than a 12 volt battery. 

 

Always disconnect the inverter when not in use. 

 

Always ensure the power cable terminal connections run Negative (-) to 

Negative (-) and Positive (+) to Positive (+). Check these connections frequently 

to make sure they remain secure. Use the heaviest gauge wire available to 

connect the inverter to the power source. While connecting the inverter to the 

power source, make certain that the inverter is positioned far away from any 

potential source of flammable fumes or gases. 

 

Always ground the inverter before operating it. Make certain the power 

consumption of the appliance or equipment you wish to operate is compatible 

with the capacity of the inverter. Do not exceed 1500 watts. When attempting to 

operate battery chargers, monitor the temperature of the battery charger for 

approximately 10 minutes. If the battery charger becomes abnormally warm, 

disconnect it from the inverter immediately. 

 

When operating the inverter with a battery that is connected to a vehicle, start the 

engine every 30 to 60 minutes and let it run for approximately 20 minutes to 

recharge the battery. In the event of a continuous audible alarm or automatic 

shut down, turn the inverter OFF immediately. Do not restart the inverter until the 

source of the problem has been identified and corrected. 

 

To avoid battery drain, always disconnect the inverter when not in use. Do not 

expose the inverter to rain or moisture. 

 

Avoid placing the inverter near sources of heat or in direct sunlight. 

 

While in use, make sure the inverter is properly ventilated. Do not operate the 

inverter near flammable materials, fumes or gases. 

 

Summary of Contents for ERP1500-12

Page 1: ......

Page 2: ...y advanced microprocessor controlled units run cooler and more reliable than any in their class Their superior surge capability allows them to start even the most difficult loads including color telev...

Page 3: ...load and it s continued running power requirements continuous load Power consumption in rated either in wattage watts or in amperes amps and this information is usually stamped or printed on most app...

Page 4: ...first connected to the inverter turn the switch ON I OFF 0 and ON I again a quick succession If this procedure is not successful it is likely that the Power Bright inverter does not have the required...

Page 5: ...dicator Light If the continuous power draw of the appliance s being operated exceeds 1500 watts this light will turn ORANGE RED and the inverter will automatically shut down When this occurs turn off...

Page 6: ...nverter exceeds the limits of safe operation the Cooling Fan automatically turns on to cool the inverter When the temperature has lowered to a safe operating mode the fan will shut off F Positive Powe...

Page 7: ...equipment or appliance divide its continuous load wattage equipment by 10 3 Conclusion The reserve power of a battery with a 150 reserve minutes rating is sufficient to satisfy the continuous load de...

Page 8: ...the 12 volt power source Then repeat this procedure with the positive Red terminal connecting a wire to the positive terminal of the 12v volt power source Make sure you have a good secure connection...

Page 9: ...on 1 Locate the Ground Lug Terminal at the rear of the inverter Run a wire from this terminal to a proper grounding point using the shortest practical length 2 AWG wire You can connect this wire to th...

Page 10: ...he television antenna produces a clear signal under normal operating conditions Also ensure that the antenna cable is properly shielded and of good quality 2 Change the positions of the inverter anten...

Page 11: ...he inverter in direct sunlight Ideal air temperature should be between 50 F and 80 F In order to properly disperse heat generated while the inverter is in operation keep it well ventilated While in us...

Page 12: ...overload capability The waveform that is generated by this conversion is a modified sine wave as shown in the diagram below 1500 WATT POWER INVERTER MODIFIED The modified sine wave produced by PowerB...

Page 13: ...of the inverter Do not exceed 1500 watts When attempting to operate battery chargers monitor the temperature of the battery charger for approximately 10 minutes If the battery charger becomes abnormal...

Page 14: ...e Use true RMS reading meter Reason Solution Battery voltage below 10 5V Recharge or replace battery Equipment being operated draws too much power Use a higher capacity inverter or do not use this equ...

Page 15: ...nput voltage below 10 5V Keep input voltage above 10 5V to maintain regulation Poor or weak battery condition Recharge or replace battery Inadequate power being delivered to the to the inverter or exc...

Page 16: ...1 6 SPECIFICATIONS Max Continuous Power 1500W Surge Capability Peak Power 3000W No Load Current Draw Rating 0 4A Waveform Modified Sine Wave Input Voltage Range 10 5 15 VDC AC Receptacles 2 x 220V AC...

Page 17: ...PA G E 1 7...

Page 18: ...icroprocesseur exc de les capacit s de la majorit des produits de m me type offerts dans l industrie tout en offrant une stabilit et une fiabilit accrues Leur puissance sup rieure permet d alimenter d...

Page 19: ...utilisez l quation suivante Intensit de courant en amp res X 220 tension CA WATTS Cette formule fournit la charge nominale continue approximative requise par l appareil Pour d terminer la puissance de...

Page 20: ...e autre source d alimentation Ne tentez pas de modifier ou d allonger le cordon d alimentation de 12 V de votre onduleur Un courant de 220 V peut tre mortel Le mauvais emploi ou le branchement inad qu...

Page 21: ...erminer la cause de la surcharge avant de r alimenter le courant de l onduleur et des appareils C 2 prises 220V AC standard D Ventilateur de refroidissement Lorsque la temp rature interne de l onduleu...

Page 22: ...qui sera n cessit amp heure appliquez la formule suivante 1 Rep rez sur l tiquette de la batterie son ratio de minutes restantes normalement retrouv es dans la section cold cranking amps CCA Si vous m...

Page 23: ...h es g n rent deux fois les amps heure comparativement une seule Trois batteries trois fois et ainsi de suite C BLES DE CONNEXION Lorsque vous branchez votre onduleur utilisez des c bles de gros calib...

Page 24: ...est normal 6 Assurez vous que l appareil que vous souhaitez utiliser est teint Branchez l appareil dans l une des deux prises CA situ es sur le panneau avant de l onduleur 7 Allumez l interrupteur de...

Page 25: ...cordon d alimentation de votre t l viseur 3 loignez votre t l viseur son cordon d alimentation et les c bles d antenne de la source 12 V en utilisant une rallonge lectrique entre l onduleur et le t l...

Page 26: ...leur tes en contact avec une surface mouill e L eau et plusieurs autres liquides sont conducteur d lec tricit et peuvent occasionner des blessures s v res ou la mort vitez de placer l onduleur pr s de...

Page 27: ...issants transistors MOFSET qui donnent une excellente capac it de surcharge Ainsi tous nos onduleurs sont capables de d marrer et de faire fonctionner des appareils qui subissent une forte surtension...

Page 28: ...r Utilisez exclusivement un fusible similaire de 40 amp res Lorsque vous utilisez la batterie comme source d nergie nous vous recommandons de d marrer le moteur de votre bateau ou de votre automobile...

Page 29: ...la batterie est inf ri eure 11 V Rechargez ou remplacez la batterie L appareil utilis demande plus de courant que la puissance de sortie de l onduleur Utilisez un onduleur plus hautes capaci t s ou ce...

Page 30: ...z la tension nominale plus de 11 V La batterie est trop faible ou en mauvaise condition Rechargez ou remplacez la batterie Le courant transmis l onduleur est inad quat ou il y a une chute de tension m...

Page 31: ...nce de sortie continue maximale 1500 W Cr tes CA maximales 3000 W Appel de courant sans charge 0 4A Onde sinuso dale modifi e Plage de tension d entr e 10 15 V DC Tension de sortie 0V CA Fusible 40 am...

Page 32: ...s par un accident un emploi abusif des r parations effectu es par l utilisateur le sable ou l eau ne sont pas couverts par cette garantie qui est seulement valable dans un centre de service Tous les f...

Page 33: ...PA G E 3 3...

Page 34: ......

Reviews: