26
x
Power Supply Unit
Input Characteristics
x
Input Voltage: Typ. 90-264VAC
x
Power Factor Correction: Meets Harmonic Correction IEC1000-3-2.
Power Factor typ. 0.95-0.97
x
Input Connector: Positronic 47-pin PCIH47M400A1
x
Input Frequency: 47-63Hz
x
Inrush Current: Less than 30A @ 230VAC
x
Input Current: 2.8A @115VAC / 1.4A @230VAC
x
Dielectric Withstand: Meets IEC950 regulation
x
EMI: Meets EN55022 / FCC Class A
x
Hold-up Time: 5mS after power fail signal
x
Remote ON/OFF: Available at [INH#] & [EN#] pins
x
Power Fail Signal: Available at [FAL#] pin
x
Status LED: <Green> means valid input voltage; <Amber> means a
critical fault.
x
Thermal Protection (OTP): Installed NTC and thermostat for thermal
sensor at [DEG#] pin
x
Power OK: Installed at all outputs
x
Leakage Current: Typ. 0.5mA
Output Characteristics
Output Current (A)
Output
Voltage
MIN.
MAX.
TYP.
PEAK.
5V
MAIN +VO1
@
Ϫ
#
Ł
Ф
2.0 33.0 25.0
!
–
3.3V
AUX. +VO2
Ÿ
@
Ϫ
#
Ł
Ф
0 33 18 –
12V
AUX. +VO3
Ÿ
Ł
#
Ф
Ϫ
@
0 5.5 5.5 6
-12V
AUX. –VO4
Ɣ
Ф
Ϫ
Ŷ
=
0 1 0.5
1.5