background image

Cooling System 

x

 21 

4

 

Cooling System 

The cPCIS-2501 is equipped with two bottom access removable fans for 
intake to provide an effectively cooled environment. The chassis is equipped 
with an air filter that is removable for cleaning and replacement.  
 

4.1 

Removing and Replacing the Air Filter 

To ensure proper performance, the air filter of cPCIS-2501 should be cleaned 
or replaced as necessary.  
 

Air Filter Removal and Replacement Procedure 

1.  Remove the screws attaching the air inlet grill on the underside of 

the chassis as shown below. 

remove screws 

Summary of Contents for cPCIS-2501

Page 1: ...cPCIS 2501 3U CompactPCI 6 slot Cubic Chassis User s Guide...

Page 2: ...This page intentionally left blank...

Page 3: ...the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright All rights are reserve...

Page 4: ...86 2 82265877 FAX 886 2 82265717 Address 9F No 166 Jian Yi Road Chungho City Taipei 235 Taiwan Please email or FAX your detailed information for prompt satisfactory and consistent service Detailed Com...

Page 5: ...3 Backplane 11 3 1 cBP 3206 Backplane 11 Specifications 11 Mechanical Drawing 12 Pin Assignment 13 3 2 cBP 3061 Power Backplane 17 Specifications 17 Mechanical Drawing 17 Pin Assignment 18 4 Cooling S...

Page 6: ...This page intentionally left blank...

Page 7: ...des maximum cooling efficiency and the 250W cPCI power supply allows easy maintenance The cPCIS 2501 s ability to handle a wide range of temperatures and excellent shock and vibration characteristics...

Page 8: ...oling System Bottom access removable fans for in take 12V DC brush less dual ball bearing Two fans with 67 02 CFM each Rated speed for each fan 4500 RPM Rated power for each fan 6 W Power Supply Power...

Page 9: ...Introduction x 3 1 4 Mechanical Drawing cPCIS 2501 Front View cPCIS 2501 Side View...

Page 10: ...This page intentionally left blank...

Page 11: ...his user s manual x Power cord either N American or European 2 2 CompactPCI Board PSU Installation CompactPCI connectors are rigid and therefore require careful handling when inserted and removed Impr...

Page 12: ...e that it is pulled downwards by first pressing on the locking button with your thumb 3 Carefully insert the module into the desired slot by sliding the edges of the board into the appropriate card g...

Page 13: ...Getting Started x 7 To remove the module press the locking button if necessary and reverse steps 1 through 5 above System Card Fully Inserted Locking Button...

Page 14: ...I PSU Installation Removal Procedure The installation and removal procedures for a CompactPCI PSU are the same as those for CompactPCI boards See the figures below Fully Latched Handle Engages with Ch...

Page 15: ...corner of the front panel to the off position I Connect the supplied power cord to the socket on the back of the chassis The supplied PSU is full range 90 240VAC and does not require input voltage se...

Page 16: ...This page intentionally left blank...

Page 17: ...x Standard CompactPCI height for 3U cPCI cards x CompactPCI Compliancy o PICMG 2 0 CompactPCI core specification R3 0 o PICMG 2 1 CompactPCI hot swap R2 0 x Dimensions 100 7 x 128 7 mm x PCI bus clock...

Page 18: ...12 x Backplane Mechanical Drawing cBP 3206 Rear View cBP 3206 Front View 1 P2 1 P1 6 P2 6 P1 CN1 CN2 JP8 JP10...

Page 19: ...ND 17 GND 3 3V IPMB_SCL IPMB_SDA GND PERR GND 16 GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY BDSEL TRDY GND 12 14 Key 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20...

Page 20: ...C NC GND 15 GND NC NC FAL REQ5 GNT5 GND 14 GND NC NC NC NC NC GND 13 GND NC NC NC NC NC GND 12 GND NC NC NC NC NC GND 11 GND NC NC NC NC NC GND 10 GND NC NC NC NC NC GND 9 GND NC NC NC NC NC GND 8 GND...

Page 21: ...GND DEVSEL GND V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY GND TRDY GND 12 14 Key 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL AD 23 GND AD 22 GND 8...

Page 22: ...3V 2 3 3V 12 12V 3 GND 13 GND 4 5V 14 PS_ON_L 5 GND 15 GND 6 5V 16 GND 7 GND 17 GND 8 POWER GOOD 18 5V 9 5V STB 19 5V 10 12V 20 5V JP8 connector Pin Signal Name 1 INH 2 12V Sense JP9 connector Pin Si...

Page 23: ...s x CompactPCI Compliancy PICMG 2 11 CompactPCI Power Interface x Dimensions 40 64x 128 7 mm x Power Module Sockets one x AC DC input screw terminal yes x DC output ATX connector one x Cascading volta...

Page 24: ...nt CN1 Power Sense Connector Pin Signal Name 1 V1_Sense 2 GND_S 3 V2_Sense 4 V3_Sense 5 NC CN2 Power Sense Connector Pin Signal Name 1 V1_Sense 2 GND_S 3 V2_Sense 4 V3_Sense 5 NC CN3 connector Pin Sig...

Page 25: ...41 V2 SHARE 25 GA0 40 IPMB_SDA 24 RTN 39 INH 23 RESERVED 38 DEG 22 RTN 37 IPMB_SCL 21 V4 36 V3 SENSE 20 V3 35 V1 SHARE 19 RTN 34 S RTN 13 18 V2 33 V2 SENSE 5 12 RTN 32 V2ADJ 1 4 V1 CN5 Current Share...

Page 26: ...D CN8 IPMB Connector Pin Signal Name 1 IPMB_SCL 2 GND 3 IPMB_SDA 4 IPMB_PWR 5 ALERT CN9 ATX Power Connector Pin Signal Pin Signal 1 3 3V 11 3 3V 2 3 3V 12 12V 3 GND 13 GND 4 5V 14 PS_ON_L 5 GND 15 GND...

Page 27: ...equipped with an air filter that is removable for cleaning and replacement 4 1 Removing and Replacing the Air Filter To ensure proper performance the air filter of cPCIS 2501 should be cleaned or repl...

Page 28: ...the remaining two screws attaching the fan module to the grill 3 After cleaning or replacing the filter place it back in position secure the fan module to the inlet grill by replacing the two screws...

Page 29: ...r Filter Removal and Replacement Procedure above Pull the fan power connectors out from behind the backplane as shown below Disconnect the power cable and replace with a functional fan module Re inser...

Page 30: ...This page intentionally left blank...

Page 31: ...5022 FCC CLASS A x CE marking compliance x Fully compliant with PICMG Specifications x Operating Temperature Range 0 C to 50 C x Storage Temperature 40 to 85 C x Temperature Coefficient Typ 0 02 C x C...

Page 32: ...egulation x EMI Meets EN55022 FCC Class A x Hold up Time 5mS after power fail signal x Remote ON OFF Available at INH EN pins x Power Fail Signal Available at FAL pin x Status LED Green means valid in...

Page 33: ...ch rail x Output Wattage Typ 250W continuous x Output Connector Positronic 47 pin PCIH47M400A1 x Line Regulation Typ 0 1 x Load Regulation Typ 1 2 x Noise Ripple Typ 1 peak to peak or 50mV whichever i...

Page 34: ...This page intentionally left blank...

Page 35: ...cket outlet shall be installed near the equipment and shall be easily accessible z Place the power cord such a way that people can not step on it Do not place anything over the power cord z If the equ...

Page 36: ...tructions z If one of the following situations arises get the equipment checked by a service personnel A The power cord or plug is damaged B Liquid has penetrated into the equipment C The equipment ha...

Reviews: