![PowerBox Systems P2-SERVOBRIDGE Instruction Manual Download Page 6](http://html1.mh-extra.com/html/powerbox-systems/p2-servobridge/p2-servobridge_instruction-manual_1588647006.webp)
6
PowerBox-Systems
− World Leaders in RC Power Supply Systems
2.
SET-UP
The P²-ServoBridge operates with a range of bus systems as well as standard
PWM servo signals. All signals are detected automatically, which means that the
device is ready to use immediately. The default settings are: Channel 1, fuse set
for servos rated at 15kg/cm to 25kg/cm output torque. The following adjustment
facilities are available at your transmitter or in PC-Terminal:
2.1 OUTPUT CHANNEL
At this point you can select the channel to be derived from the bus signal: this will
be generated as a PWM servo signal.
2.2 FRAME RATE
The frame rate refers to the speed at which the PWM signal is repeated at the
ServoBridge’s output. Modern digital servos generally operate without problem at
the 12ms setting, but the frame rate should be set to the slower 18ms value for use
with earlier analogue servos. If in doubt, your servo manufacturer will be able to
provide accurate information.
2.3 SERVO TYPE
Four different pre-set servo templates can be selected at the P²-ServoBridge:
Micro, Midi, Standard and Hi-Torque. Of course, you can also adjust the set values
for the two fuse thresholds individually if you wish.