Admiral 38C Scrubber PB# 4100055UM Rev.* 08/10
PowerBoss, Inc. Copyright 2010
Page 49
Operation
Table 1
3.5.2
Other function faults
The vehicle does not work
Check the fuses, refer to Section
5.10.3.
In the event of faults in the trac-
tion drive, stop the vehicle imme-
diately, apply the parking brake
and remove the key!
Error code
Fault
Cause
Solution
2.3.5.1
The side brushes remain stopped
because the thermostatic switch
has been tripped.
The motor has overheat-
ed. Foreign bodies have
possibly jammed be-
tween the side brushes
and shaft (e.g. tape and
such).
• Check the side brushes for foreign bodies
and remove them, as necessary.
• Allow the motor to cool down.
• If the problem reoccurs, determine the
cause of overheating; contact an authorized
PowerBoss service center, if necessary.
2.3.6.1.
The side brushes remain stopped
because the anti-blocking system
has been tripped.
Foreign bodies (e.g.
tape or such) are block-
ing the side brushes
• Check the side brushes for foreign bod-
ies and remove them, as necessary.
2.3.6.4.
The side brush holding attachment has
been switched off because the anti-
blocking system has been tripped.
Foreign bodies between
the side brush unit and
vehicle
• Check the side brush unit for foreign
bodies and remove them, as necessary.
1.4.6.1.
The squeegee holding attachment has
been switched off because the anti-
blocking system has been tripped.
• Foreign bodies between
the squeegee and
vehicle.
• Squeegee is jammed
• Check the holding attachment for foreign
bodies and remove them, as necessary.
• Free the squeegee.