For Internal Office Use Only
9.2 SETTING THE ACCELERATOR PETAL
Setting the drive rheostat switch S8 and the drive rheostat ‘R1‘ at
the accelerator
pedal is required.
Caution:
Before proceeding to settings at the drive control unit make sure
that the drive wheel
rotates freely and has no contact with the ground. The setting
work has to be
executed with the greatest precaution possible to preclude
injuries of persons or a
movement of the machine, since otherwise the wheels may
suddenly start rotating.
Make sure that garments, hair, measuring cables or other are not
caught in the
rotating wheel (risk of injury!).
Before starting work, set the direction limit switch ‘S7‘ to ”0”.