9
www.powerboozt.com
EN
5.3
Dip Switcher (RHINO-L series only )
S4 - 50/60Hz adjustable (I on position means 60Hz, O off position means 50Hz)
S3- Sleeping mode activated, if load less 5% of rated power. e.g: 2000w less 100w then
S2- Sleeping mode activated, if load less 10% of rated power.
S1- Sleeping mode activated, if load less 15% of rated power.
5.4
USB output
All models have an USB port. Here you can connect your 5Volt users, like mobile phone charger, directly. The
maximum load for this output is 2,1Amp.
5.5
Remote control
If the remote controller CR80 or CRD80 or CRW80 is connected, it is important that the main switch of the inverter
is in the ‘off’ position. After this, the inverter can be switched on and off by using the remote control.
5.6
LCD display function (optional)
It display the battery voltage (V), output power(W) , battery capacity( Ah), lower voltage protection, over voltage
protection, over load protection, over temperature protection.
5.7
Fan
The fan is both temperature- and load controlled. At a certain load level, depending per model, the fan will switch
on automatically. Also at an internal high temperature the fan will switch on automatically.
What does the inverter consume from the battery?
A quick formula which gives a global indication of the current draw from the battery is:
Watt : voltage = current draw per hour
Example: a 1500Watt inverter in 12Volt consumes at full load:
1500W : 12V = 125Amp. per hour. Has the inverter delivered this power for 5 minutes, then the current
draw from the battery is about 10Amp.
Remark: when a 1500Watt inverter delivers a power of 600Watt, then it consumes also only 600Watt from
the battery.