power-xtra PX7500WB Quick Start Manual Download Page 7

• The warranty period of a battery is half a year from the delivery date of shipment. The detective product caused by 

Power-Xtra GROUPE INTERNATIONAL LIMITED will be returned within the warranty period.
• For the use of the battery exactly, in order to obtain optimum performance and safety, the Customer shall strictly observe 

this item described below. The defects other than those caused by user overstep this Specification shall be excluded from the 

warranty of Power-Xtra GROUPE INTERNATIONAL LIMITED
• Any matters which are not covered in this specification should be negotiated between the customer and Powe-Xtra.

Product Cautionary Statement and Disclosure

User manual

Warranty period of battery and Quality guarantee

Power-Xtra GROUPE INTERNATIONAL LIMITED, Ltd will not take any responsibility for the problems caused by incorrect 

operation beyond the specification.

Note(1):

 The battery might be at an over-discharged state because of its self-discharge characteristics if the battery is not 

used for long time. In order to prevent over-discharging, the battery should be charged (at least once every three months)

periodically to maintain the voltage between (3.7V and 3.9V)*N ((n represents the number of series of cell)).

Note(2): 

Power-Xtra GROUPE INTERNATIONAL LIMITED, Ltd will not take any responsibility for the problems caused by 

improper use of PCM, battery pack, RC model and charger.

Note(3): 

It is necessary to use the charger with protection balanced function to charge if the finished battery without PCM.

Note(4): 

Power-Xtra GROUPE INTERNATIONAL LIMITED, Ltd will not take any responsibility for products beyond the warranty 

period.

Note(5): 

The charging current can’t exceed the maximum charging current in this specification; The charging with higher 

current than recommended value may caused the problems of performance of charge & discharge, mechanical and safety,

and may lead to fever or leakage. The maximum charging voltage can’t exceed this specification.

Note(6): 

The cell shall be discharged at less than the maximum discharge current specified in the Product Specification

; 

High discharging current may reduce the discharging capacity significantly or cause over-heat.

Note(7): 

Power-Xtra will not take any responsibility for battery damaged resulting from the client assembly after the products 

were accepted.

• Stop using the battery immediately whenever it deforms, swells, leaks.

• Check the total output of the battery pack if the appearance is normal. Within one month of shipment, the total output is 

within the standard as specification sheet shows, confirmed it is OK if in this range;

• Once the total voltage output is confirmed OK, test each cell voltage. Within one month of shipment, the standard of the 

single cell output is in the range of 3.70V ~ 3.96V, and it is OK again if it is in this range;

• Once the total voltage and cell voltage are confirmed OK, test the total internal resistance through the discharge wire, if its 

total internal resistance standard is within the standard range as specification sheet shows, it is OK for normal using.

• The battery might be in over-discharge status because of its self-discharged characteristics if no battery operation for a 

long time. To prevent over-discharge occurs, the battery should be charged regularly to maintain its power between 30%

~60%. Over-discharge will lead to the loss of battery function;

• Battery long-term storage process, the remaining capacity should be between 30 to 60%, about 50% at best status. High 

voltage storage conditions will accelerate the self-discharge, increase the side reaction products, and may damage the

battery performance;

• Battery long-term storage temperature is 0

 ~ 30 

, for the storage period of more than 3 months, battery pack needs to 

be activated before use. Activation means that charge the battery pack with a balanced charger, charging until the

electricity is displayed at 100% SOC, then discharged at a current of 0.2CmA to the voltage protection, and then charge the 

battery to about 50% SOC with the balance charger;

• Do not discharge battery pack with less than 3.2V * N (N refers to the number of batteries in series) otherwise it will lead to 

the battery pack performance degradation and shorten its cycle life;

• Recommend to remain no less than 20% of the battery electricity after the end of using.

Notice

MODEL      

STOCK NO 

:

:

PX7500WB

900.869.503.159

Battery Solutions

www.power-xtra.com

Summary of Contents for PX7500WB

Page 1: ...t of the finished product specification data sheet please kindly confirm in time The specification of the product after the product finalized is effective only after both of the two parties the manufacturer and the customer sign and stamp with a across page seal on As the specification of the drawings is only the schematic drawings there may be some difference with the physical objects Power Xtra ...

Page 2: ...rat on Max Charge Voltage 16 8V 4 2V Cell Sh pments of Open c rcu t voltage 14 8 15 84V Test w th n 30 days from the date of sh pment Internal res stance 23 4mΩ Test through the d scharg ng w re term nal Standard D scharge current 7 5 A 1 0C Burst D scharge Current 337 5A 45C Standard charge current 7 5A 1 0C Max mum charge current 15 0A 2 0C Ref Temperature 10 45 Overcharg ng protect on Voltage 4...

Page 3: ...charge 1 0CmA 7500mA CC Discharge cut off Voltage 12 0V Standing Time Unless otherwise specified between battery charging and discharging there is a 30min interval or more Item Testing method Requirement Open circuit voltage 16 4V Measure the open circuit voltage of the battery within 24 hours after the Standard Charge AC Resistance Resistance of Battery Pack 23 4mΩ After half charge measure the r...

Page 4: ...for 3 cycles Measure the recovery capacity The Max discharge capacity for three cycles 2 2 Item Testing method Requirement Constant humidity a d temperature test Vibration test Free drop test Discharge Capacity 80 C1 0 The battery have no obvious defaced no leakage no fire or no explosion The battery have no obvious defaced no leakage no fire or no explosion Remaining Capacity 85 C1 0 Recovery cap...

Page 5: ...anode and cathode tap of the battery are parallel with Title No Specifications Remark Unit Qty 1 cell 5644129XL PCS 8 JST XHR 5P 3239 22 PCS 1 3239 10 PCS 2 33 1 2 3 4 75 RH 30 60 Storage and Shipment Requirement PCM Circuit Diagram PCM Electrical Characteristics PCM Material List Mounting structure Battery materials Item Requirement Remarks Storage temperature Humidity State of Charge SOC The bes...

Page 6: ... Inner packaging The photo size and color of the mark are all comply with the requirement of GP T 191 2000 Battery Dimension Unit mm and Structure MODEL STOCK NO PX7500WB 900 869 503 159 Battery Solutions www power xtra com ...

Page 7: ...gh discharging current may reduce the discharging capacity significantly or cause over heat Note 7 Power Xtra will not take any responsibility for battery damaged resulting from the client assembly after the products were accepted Stop using the battery immediately whenever it deforms swells leaks Check the total output of the battery pack if the appearance is normal Within one month of shipment t...

Page 8: ...re for example at strong direct sunlight or in a vehicle in extremely hot weather Otherwise it can overheat or fire or its performance will be degenerate and its service life will be shortened Do not use it in a location where static electricity is rich otherwise the safety devices may be damaged causing a harmful situation In case the electrolyte getting into the eyes due to the leakage of batter...

Reviews: