power-xtra PX7500WB Quick Start Manual Download Page 3

Testing method and conditions

Performance

Standard test conditions

Measuring Equipment requirements

Standard Charge

Electricity Characteristics

The battery for test must be new produced no more than 1 month. Unless otherwise specified, all tests stated in this Specifi-

cation shall be proceeded in the following conditions:

Temperature of 23±2

, the relative humidity of 45%~65%RH, atmospheric pressure is 86kPa~106kPa

• Slide caliper should have an accuracy of the grade 0.01mm or higher.

• The multimeter should have an accuracy of the grade 0.5 or higher. The impedance when testing voltage should be more 

than 10KΩ/V.

• The impedance meter with AC 1 kHz should be used.

• For the battery testing system, the accuracy of current should be more than ±0.1%, the accuracy of voltage should be more     

than ±0.5% and the accuracy of time should be more than ±0.1%.

• The thermometer should be have an accuracy of the grade 0.5

 or higher.

1.0CmA (7500mA) 16.8V (CC-CV) ,Cut-off current is 0.05CmA

Note:

 Charging equipment special for Lithium-ion Polymer battery must be used only for the above charging.

Standard Discharge

1.0CmA(7500mA) CC Discharge cut-off Voltage 12.0V

Standing Time

Unless otherwise specified, between battery charging and discharging, there is a 30min interval or more.

 

Item

 

Testing method

   

Requirement

 

Open-circuit voltage

16.4V

Measure the open-circuit voltage of the battery

within 24 hours after the Standard Charge

AC Resistance

Resistance of

Battery Pack

23.4mΩ

After half charge, measure the resistance through

the discharge wires at AC 1KHz ,23±2

Capacity

Discharge Capacity

≥ 

100%

 (

min Capacity

Discharge the battery with a constant current of

0.2CmA(1500mA) to 12.0V after Standard

Charge and rest 30min

Cycle Life Performance

Cycle Life

300 cycles

Discharge Capacity

80%

Measure capacity under the cycle conditions

described below, until the discharge capacity

80% for three times. Cycle conditions: Standard

Charge

CC-CV

7500mA

16.8V

) , 

Rest for

30min; Discharge with 1C, 12.0V cutting off.

Testing temperature is 23±2

Discharge Temperature

Characteristics

-20

60%

25

100%

60

95%

Heat or cool the battery to the testing temperature

within 30min and rest for 3 hours after standard

charge at 23±2

, then discharge at 1.0CmA .

When a test finished, charge the battery after

rested 2 hours at room temperature

 

(23±2

)

 

 

MODEL      

STOCK NO 

:

:

PX7500WB

900.869.503.159

Battery Solutions

www.power-xtra.com

Summary of Contents for PX7500WB

Page 1: ...t of the finished product specification data sheet please kindly confirm in time The specification of the product after the product finalized is effective only after both of the two parties the manufacturer and the customer sign and stamp with a across page seal on As the specification of the drawings is only the schematic drawings there may be some difference with the physical objects Power Xtra ...

Page 2: ...rat on Max Charge Voltage 16 8V 4 2V Cell Sh pments of Open c rcu t voltage 14 8 15 84V Test w th n 30 days from the date of sh pment Internal res stance 23 4mΩ Test through the d scharg ng w re term nal Standard D scharge current 7 5 A 1 0C Burst D scharge Current 337 5A 45C Standard charge current 7 5A 1 0C Max mum charge current 15 0A 2 0C Ref Temperature 10 45 Overcharg ng protect on Voltage 4...

Page 3: ...charge 1 0CmA 7500mA CC Discharge cut off Voltage 12 0V Standing Time Unless otherwise specified between battery charging and discharging there is a 30min interval or more Item Testing method Requirement Open circuit voltage 16 4V Measure the open circuit voltage of the battery within 24 hours after the Standard Charge AC Resistance Resistance of Battery Pack 23 4mΩ After half charge measure the r...

Page 4: ...for 3 cycles Measure the recovery capacity The Max discharge capacity for three cycles 2 2 Item Testing method Requirement Constant humidity a d temperature test Vibration test Free drop test Discharge Capacity 80 C1 0 The battery have no obvious defaced no leakage no fire or no explosion The battery have no obvious defaced no leakage no fire or no explosion Remaining Capacity 85 C1 0 Recovery cap...

Page 5: ...anode and cathode tap of the battery are parallel with Title No Specifications Remark Unit Qty 1 cell 5644129XL PCS 8 JST XHR 5P 3239 22 PCS 1 3239 10 PCS 2 33 1 2 3 4 75 RH 30 60 Storage and Shipment Requirement PCM Circuit Diagram PCM Electrical Characteristics PCM Material List Mounting structure Battery materials Item Requirement Remarks Storage temperature Humidity State of Charge SOC The bes...

Page 6: ... Inner packaging The photo size and color of the mark are all comply with the requirement of GP T 191 2000 Battery Dimension Unit mm and Structure MODEL STOCK NO PX7500WB 900 869 503 159 Battery Solutions www power xtra com ...

Page 7: ...gh discharging current may reduce the discharging capacity significantly or cause over heat Note 7 Power Xtra will not take any responsibility for battery damaged resulting from the client assembly after the products were accepted Stop using the battery immediately whenever it deforms swells leaks Check the total output of the battery pack if the appearance is normal Within one month of shipment t...

Page 8: ...re for example at strong direct sunlight or in a vehicle in extremely hot weather Otherwise it can overheat or fire or its performance will be degenerate and its service life will be shortened Do not use it in a location where static electricity is rich otherwise the safety devices may be damaged causing a harmful situation In case the electrolyte getting into the eyes due to the leakage of batter...

Reviews: