background image

 

Control Panel 

 

Four levels and five positions rotary switch, which can be turned from 0 to 360 degree 

clockwise  or  counter  clockwise,  the  first  level  is  ventilator  only,  the  second  level  is 

1,5KW, the third level is full power input. You can adjust the level clockwise or reverse. 

0 40

°

C adjustable thermostat to control the room temperature the thermostat button 

can be turned from 0 to 270 degree. 

THERMOSTAT INSTRUCTIONS   

At first turn the thermostat to “Max” and let the heater operate with full power input. 

When the room temperature reaches the required value, turn the thermostat to left until 

it switches off. 

The thermostat will then switch on and off automatic to control the room temperature 

according to the preset value and keep the room temperature constant. 

 

Manual reset thermal cut-out

   

By overheating or abnormal operation and meanwhile the thermostat fails to work, the 

manual resetting thermal cut-out will act and shut down the appliance. Remove the plug 

from the socket and let the appliance cool down, then use the provided steel pin to 

touch the manual resetting button. When you hear a clear click it means the electric 

circuit is put through, put the plug back into the socket and switch the heater on. see the 

figure manual “RESET” button  

When using the heater for the first time, you may notice a slight emission of smoke. This 

is quite normal and it stops after a short time. The heating element is made of steel and 

was coated with a layer of protection oil by production. The smoke is caused by the left 

oil when heated. 

Summary of Contents for EL 3

Page 1: ...Industrial fan heater EL 3 User manual ...

Page 2: ...s the temperature of air outlet It will switch off the heater by overheating to ensure the safe use The fan motor is not controlled by thermostat When the thermostat cuts off the heating element the ventilator keeps working on Technical data Model Frame structure Voltage Power input Packing Dimensions m Gross weight Power Tec EL 3 steel frame 230V 50Hz 3 kW 0 33 x 0 32 x 0 47 6 kg Fuse capacity mu...

Page 3: ...control the room temperature according to the preset value and keep the room temperature constant Manual reset thermal cut out By overheating or abnormal operation and meanwhile the thermostat fails to work the manual resetting thermal cut out will act and shut down the appliance Remove the plug from the socket and let the appliance cool down then use the provided steel pin to touch the manual res...

Page 4: ...eater in the bathroom shower or near a swimming pool etc 5 Do not place the appliance on moving vehicles or some where easy to be tipped over 6 When you don t use the appliance for a long time unplug the appliance Don t leave the heater for a considerable amount of time when in use Pull the plug straight out never remove the plug by pulling on the cord 7 Use the appliance in places with good air v...

Page 5: ...t keep it dry Then cover it with a plastic bag put in the packing box and store it in a dry ventilated place Trouble shooting You can solve many common problems easily saving you the cost of a possible service call Try the suggestions below to see if you can solve the problem before calling the service centre Problem Possible cause Treatment The plug is loose bad connection Pull out the plug check...

Page 6: ...2 stick and insert it in the manual reset hole on the control panel press down the reset button and connect the circuit Abnormal noise The appliance is not level Put the heater on a level surface the switch delay time is very long or the power can not be cut off The ambient temperature is high Use the appliance under 25 ambient When the room temperature is higher than 25 and the delay time is too ...

Page 7: ... Dworcowa 34 64 500 Szamotuły Poland herewith declare that the below mentioned product Electric heater POWER TEC EL 3 meet the provisions of the following EC directives and standards LVD 2006 95 EC EMC 2004 108 EC Szamotuły 14 07 2010 ...

Reviews: