Installation Instructions for Power Sentry Emergency Battery Packs 

–QD MVOLT Series

     

                     

 

 

Page 7 

 

CONNECT RED WIRE TO POINT “A” 

FOR ONE LAMP  OR TO POINT “B” 

FOR TWO LAMP EMERGENCY 

OPERATION

CAUTION

REFER TO LAMP SELECTOR TABLE 

BEFORE CHANGING POSITIONS

LAMP SELECTOR (PS 1400 ONLY)

BALLAST POWER  CONNECTION 
120 TO 277 VAC SWITCHED OR 
UNSWITCHED LINE – 
NOTE; VERIFY VOLTAGE RATING 
ON LAMP BALLAST

CONNECT BLACK AND ORANGE 
LEADS TOGETHER IF ORANGE 
WIRE IS PRESENT

120 TO 277 VAC 

UNSWITCHED LINE 

TEST SWITCH/PILOT LIGHT

SINGLE 

EMERG. LAMP 

CONNECTION

“A”

 TWO EMERG. LAMP CONNECTION

“B”

MVOLT

BATTERY PACK

THREE LAMP RAPID START BALLAST

Figure C 

 

FOUR LAMP RAPID  START BALLAST 

SINGLE 

EMERG. LAMP 

CONNECTION

“A”

“B”

 TWO EMERG. LAMP CONNECTION

CONNECT RED WIRE TO POINT “A” 

FOR ONE LAMP  OR TO POINT “B” 

FOR TWO LAMP EMERGENCY 

OPERATION

BALLAST POWER  CONNECTION 
120 TO 277 VAC SWITCHED OR 
UNSWITCHED LINE – 
NOTE; VERIFY VOLTAGE RATING 
ON LAMP BALLAST

CONNECT BLACK AND ORANGE 
LEADS TOGETHER IF ORANGE 
WIRE IS PRESENT

120 TO 277 VAC 

UNSWITCHED LINE 

LAMP SELECTOR (PS 1400 ONLY)

CAUTION

REFER TO LAMP SELECTOR TABLE 

BEFORE CHANGING POSITIONS

MVOLT

BATTERY PACK

TEST SWITCH/PILOT LIGHT

Figure D

 

 
 

Summary of Contents for PS 300 MVOLT

Page 1: ...e this equipment for other than its intended use IMPORTANT SAFEGUARDS Consult your local building code for approved wiring or installation The emergency battery pack must be connected to an un switched AC power source of 120 to 277 Vac This product is for use with indoor fixtures sealed or unsealed Equipment should be mounted in a location and at heights where it will not be readily be subject to ...

Page 2: ...ower Connector Inspect that the Wire Harness Plug is squarely seated against the Battery Pack Power Connector 7 Insert a wire tie into the flat wire tie holder and pull the wire tie tight as shown in Figure 3 8 Inspect that the Wire Harness Plug is still squarely seated against the Battery Pack Power Connector Figure 2 Figure 3 Step 2 Install Test Switch Pilot Light TS PL CAUTION Fixture contains ...

Page 3: ...ttery Pack switches the fixture back to the normal mode in 3 5 seconds Periodic Maintenance Emergency lighting system should be tested per all of the required tests and as often as local codes require or at least quarterly to insure all components are operational 1 Periodically manually test the emergency lighting system by pressing the TS PL test button 2 Insure the Red LED charging light is on w...

Page 4: ... 1 1 1 2 SINGLE or BIPIN 14 24W 2 4 1 UP 2 DOWN SINGLE or BIPIN 28 40W 2 4 1 UP 2 DOWN 40 215W 5 8 1 DOWN T5HO BIPIN G5 24 54W 2 4 1 DOWN Long Compact PL 4 PIN 2G11 18 39W 1 UP 2 DOWN 40 55W 1 DOWN Compact PL 4 PIN G24 GX24 13 26W Quad Tube 1 UP 2 DOWN 4 PIN G24 GX24 18 26W Triple Tube 1 UP 2 UP 4 PIN G24 GX24 32W Triple Tube 1 UP 2 DOWN 4 PIN GX24 42W Triple Tube 1 DOWN If the sum of the Emergenc...

Page 5: ... 1 2 1 2 2 4 17 32W 1 1 1 2 1 2 5 8 40 59W 1 1 HO 8 86W 1 1 T9 CIRCLINE 20 40W 1 1 2 T12 U LAMP 34 40W 1 1 1 2 1 2 2 4 20 40W 1 1 1 2 1 2 5 8 50 75W 1 1 HO 2 4 35 60W 1 1 HO 5 8 70 110W 1 1 VHO 2 4 74 115W 1 1 VHO 5 8 135 215W 1 1 PL Twin Tube 4 PIN 9 13W 1 Quad Tube 4 PIN 13 26W 1 2 Triple Tube 4 PIN 18 32W 1 2 42W 1 Long Compact 2G11 18 40W 1 1 1 50 55W 1 One lamp operation in emergency mode can...

Page 6: ... TO 277 VAC UNSWITCHED LINE MVOLT BATTERY PACK ONE LAMP RAPID START BALLAST RED BLUE BLUE RED RED RED Figure A TWO LAMP RAPID START BALLAST SINGLE EMERG LAMP CONNECTION CONNECT RED WIRE TO POINT A FOR ONE LAMP OR TO POINT B FOR TWO LAMP EMERGENCY OPERATION CONNECT BLACK AND ORANGE LEADS TOGETHER IF ORANGE WIRE IS PRESENT 120 TO 277 VAC UNSWITCHED LINE BALLAST POWER CONNECTION 120 TO 277 VAC SWITCH...

Page 7: ...LINE TEST SWITCH PILOT LIGHT SINGLE EMERG LAMP CONNECTION A TWO EMERG LAMP CONNECTION B MVOLT BATTERY PACK THREE LAMP RAPID START BALLAST Figure C FOUR LAMP RAPID START BALLAST SINGLE EMERG LAMP CONNECTION A B TWO EMERG LAMP CONNECTION CONNECT RED WIRE TO POINT A FOR ONE LAMP OR TO POINT B FOR TWO LAMP EMERGENCY OPERATION BALLAST POWER CONNECTION 120 TO 277 VAC SWITCHED OR UNSWITCHED LINE NOTE VER...

Page 8: ... LAMP BALLAST 120 TO 277 VAC UNSWITCHED LINE MVOLT BATTERY PACK Figure E CAUTION REFER TO LAMP SELECTOR TABLE BEFORE CHANGING POSITIONS LAMP SELECTOR PS 1400 ONLY TEST SWITCH PILOT LIGHT CONNECT BLACK AND ORANGE LEADS TOGETHER IF ORANGE WIRE IS PRESENT 120 TO 277 VAC UNSWITCHED LINE MVOLT BATTERY PACK BALLAST POWER CONNECTION 120 TO 277 VAC SWITCHED OR UNSWITCHED LINE NOTE VERIFY VOLTAGE RATING ON...

Page 9: ... LAMP BALLAST MVOLT BATTERY PACK ONE LAMP INSTANT START BALLAST Figure G CONNECT BLACK AND ORANGE LEADS TOGETHER IF ORANGE WIRE IS PRESENT CONNECT RED WIRE TO POINT A FOR ONE LAMP OR TO POINT B FOR TWO LAMP EMERGENCY OPERATION CAUTION REFER TO LAMP SELECTOR TABLE BEFORE CHANGING POSITIONS LAMP SELECTOR PS 1400 ONLY TEST SWITCH PILOT LIGHT 120 TO 277 VAC UNSWITCHED LINE MVOLT BATTERY PACK BALLAST P...

Page 10: ...AGE RATING ON LAMP BALLAST SINGLE EMERG LAMP CONNECTION A B TWO EMERG LAMP CONNECTION MVOLT BATTERY PACK THREE LAMP INSTANT START BALLAST Figure I CONNECT RED WIRE TO POINT A FOR ONE LAMP OR TO POINT B FOR TWO LAMP EMERGENCY OPERATION SINGLE EMERG LAMP CONNECTION A TWO EMERG LAMP CONNECTION B CONNECT BLACK AND ORANGE LEADS TOGETHER IF ORANGE WIRE IS PRESENT TEST SWITCH PILOT LIGHT 120 TO 277 VAC U...

Page 11: ...DS TOGETHER IF ORANGE WIRE IS PRESENT 120 TO 277 VAC UNSWITCHED LINE TEST SWITCH PILOT LIGHT MVOLT BATTERY PACK ONE LAMP CIRCLINE BALLAST Figure K LAMP SELECTOR PS 1400 ONLY CAUTION REFER TO LAMP SELECTOR TABLE BEFORE CHANGING POSITIONS TEST SWITCH PILOT LIGHT BALLAST POWER CONNECTION 120 TO 277 VAC SWITCHED OR UNSWITCHED LINE NOTE VERIFY VOLTAGE RATING ON LAMP BALLAST CONNECT BLACK AND ORANGE LEA...

Page 12: ...GE WIRE IS PRESENT 120 TO 277 VAC UNSWITCHED LINE MVOLT BATTERY PACK ONE LAMP WITHOUT AC BALLAST Figure M CAUTION REFER TO LAMP SELECTOR TABLE BEFORE CHANGING POSITIONS LAMP SELECTOR PS 1400 ONLY CONNECT BLACK AND ORANGE LEADS TOGETHER IF ORANGE WIRE IS PRESENT 120 TO 277 VAC UNSWITCHED LINE TEST SWITCH PILOT LIGHT TWO LAMP WITHOUT AC BALLAST MVOLT BATTERY PACK Figure N www powersentrysafety com 1...