42
Englis
h
6.1 Voltage selector 400V
– 230V
Choose in the selector of control panel 3Phase 400V or 1phase 230V according
equipment that will be connected in generator.
6.2 Use of the 230V or 400V AC sockets.
NOTE: Check that no devices are plugged into the generator, unplug
everything before starting the engine.
Start the engine following the steps indicated in this manual.
Once started, verify that the overload protection (BREAKER) is in the "ON"
position, now you can connect your devices.
In order to improve the engine operation and extend the life of the machine, we
recommend a "break-in period" of 20 hours without forcing the generator, with
charges that do not exceed 60% of the equipment's maximum output.
WARNING:
Confirm that all electrical devices are in good work conditions
before plugging them to the generator.
If an electrical device is not working properly, is slow or stops suddenly, turn off
the engine immediately and unplug the device.
230V 32AH SOCKET BREAKER
16AH AC SOCKET BREAKER
GENERAL BREAKER 400V