![Power Probe PPDCM80 User Manual Download Page 8](http://html.mh-extra.com/html/power-probe/ppdcm80/ppdcm80_user-manual_1587603008.webp)
- 8 -
- 9 -
7HFKQLFDO6SHFL¿FDWLRQV
AC Current
Range
Resolution
Accuracy
4 A
1 mA
±(2.5% of r5 digits)
40 A
10 mA
80 A
100 mA
• Max. input current: 80A AC
• Frequency range: 40Hz~400Hz
DC Current
Range
Resolution
Accuracy
4 A
1 mA
± (2,5 % of r 5 digits)
40 A
10 mA
80 A
100 mA
• Max. input current: 80A DC
DC Voltage
Range
Resolution
Accuracy
4 V
0,001 V
± (0,8 % of r 3 digits)
40 V
0,01 V
400 V
0,1 V
600 V
1 V
•
,QSXWLPSHGDQFH0ȍ
• Max. input voltage: 600V DC
Note:
At small voltage ranges, unsteady readings will appear before the test leads make
contact with the circuit. This is normal since the meter is highly sensitive. When the
test leads are connected to the circuit, the true reading will be shown.