ELECTRICAL WARNING 

 

Keep the unit clean only by dusting it with a dry cloth. DO NOT get it overly moist, or physical 
damage may result. 

 

 

Caution 

 

If the UPS will be stored for long periods of time, the battery must be charged once for every 60 days 
of storage. 

 
 
 

Summary of Contents for INTegral Line 650 VA

Page 1: ...INTegral Line Interactive Uninterruptible Power Supply Unit 650 VA Power Innovations 1 Line Interactive Uninterruptible Power Supply Unit 650 VA USER S MANUAL MNL105 650VA T ...

Page 2: ...GS Read and follow installation instructions carefully before operating Applying information contained in this manual to any other product may cause injury The INTegral is registered for sale by Power Innovations International Inc This manual may have been received with other products or instructional materials If additional products or instructional materials have been ordered but have not been r...

Page 3: ...4 4 4 No Outputs Connected 14 4 5 System Power OFF 14 4 5 1 While Connected to Input 14 4 5 2 While in Battery Backup Mode 14 4 6 Storing the System 14 5 1 Maintenance 16 5 2 Troubleshooting Tables 16 5 2 1 Utility Power Functioning 16 5 2 2 Utility Power Failing 17 7 1 Limited Warranty 20 7 1 1 Shipment and Power up Dates 20 7 1 2 Warranty Inclusions 20 7 2 Part Replacement and Servicing 20 7 2 1...

Page 4: ...ment needs reliable clean power The Uninterruptible Power System UPS is designed to meet all computer server and automated office equipment needs with a compact quiet unit that operates efficiently and provides multiple interface options To choose the INTegral 650LED as your equipment protector is a wise investment because it supplies reliable pure and stable power at an affordable price 1 1 1 Key...

Page 5: ...belong with the rest Some of the information is very important while other information may be good to know To show the importance of each piece of information the following symbols and formatting conventions are used WARNINGS Denotes advice that if not followed could cause severe bodily harm or death due to electrical shock Denotes advice that if not followed could cause severe bodily harm or deat...

Page 6: ... Power Mode When functioning normally the system will power the load and charge batteries to operate when utility power is unstable This method of battery backup provides a cost effective means of providing reliable uninterruptible power and increasing UPS efficiency to save you money In the AC loop the power comes from AC utility input such as a wall outlet and passes through a static switch to s...

Page 7: ... stable AC sine wave to power even the most sensitive equipment Power will pass from the battery through the DC DC converter DC AC inverter and static switch to provide output for the full length of the battery charge Actual battery backup time will vary depending upon initial battery charge and the current load percentage See 6 Specifications for backup time estimates Figure 5 Power flow during B...

Page 8: ...wer cables before moving the system While moving the system handle it carefully The combined weight of the unit and its batteries can be significant It is recommended that the system be transported in the original packaging ELECTRICAL WARNING DO NOT transport the system with power cables still attached Failure to heed this warning could cause accidental electrical shock or death by electrocution C...

Page 9: ...light or weather Near any source of natural or artificial heat With less than 1 in of ventilation room on all sides with visible ventilation holes Avoid locations where the system Could be exposed to flammable gases or corrosive liquids Will be cooler than 32 F 0 C or hotter than 104 F 50 C Will be exposed to clutter or objects that could block ventilation openings Cannot ventilate Environment Ide...

Page 10: ...ectly place a tower system set it on its vertical bottom end Placing the system on its sides front or rear will inhibit UPS operation For more information about socket locations refer to 1 1 1 Key Features Figures 6 and 7 Ventilation clearances for the INTegral system 3 2 Connecting Systems For product keys showing the socket locations and other interface connection options located on the casing s...

Page 11: ...ter the hardware has been connected to the port the monitoring software is ready to be connected to a computer and configured Additional Manual Connect the unit to the computer to monitor it If UPQsoft or UPQNet Agent9 has been ordered another manual will be included 3 2 1 Prestart Checklist The UPS is positioned correctly The input cord is secured The rated input voltage from the wall socket fall...

Page 12: ...This page intentionally left blank ...

Page 13: ...r unplug the system from the wall outlet unless all breakers have been turned OFF This will cause the system to switch to backup mode and drain the batteries ELECTRICAL WARNING Disregarding the preceding advice may directly cause or contribute to injury Caution Disregarding the preceding advice may harm the system and void the system warranty 4 1 System Power ON Once the UPS is connected to the po...

Page 14: ...conds Note The UPS buzzer will be enabled automatically in severe cases such as overload overheat or low battery conditions 4 4 No Outputs Connected When power is not being transferred to the load the UPS will beep and the green light will flash For more information see 5 Troubleshooting 4 5 System Power OFF Press the LED light button for two 2 seconds The system will beep twice as it turns OFF 4 ...

Page 15: ...wer Innovations 15 ELECTRICAL WARNING Keep the unit clean only by dusting it with a dry cloth DO NOT get it overly moist or physical damage may result Caution If the UPS will be stored for long periods of time the battery must be charged once for every 60 days of storage ...

Page 16: ...rviced except by authorized individuals Opening the case could cause accidental injury or death due to the enclosed batteries Follow the troubleshooting guide If troubleshooting does not fix the problem call Power Innovations 5 2 1 Utility Power Functioning Scenario Possible Cause Try AC utility power is normal UPS is running normally Buzzer is continual Fan is damaged Replacing the fan Unknown Re...

Page 17: ...e Reducing the critical load to extend backup time AC input may not be connected correctly Checking the input rate Checking power connection AC utility power fails UPS is in battery backup mode Buzzer beeps every second Battery power is approaching low levels UPS will shut down automatically Save data or disconnect loads soon AC utility power fails UPS has shut down automatically Battery has run o...

Page 18: ... 1 Hz Power Factor 0 625 Wave Form Pure Sine wave Efficiency Line Mode 98 Battery Mode 80 Short Circuit Protection Line Mode Circuit Breaker Battery Mode Electronic Circuit DC Start Cold Start Yes Transfer Time Typical 4 ms Battery Battery Voltage 12VDC Battery Type 9AH 8 5AH Battery Quantity 1 pce Backup Time 50 Load 6 30 Backup Time 100 Load 1 30 Recharging current 0 1C Control Panel LED display...

Page 19: ...INTegral Line Interactive Uninterruptible Power Supply Unit 650 VA Power Innovations 19 This page intentionally left blank ...

Page 20: ...fications of the original parts or unit 7 2 1 Restrictions 7 2 1 1 UNAUTHORIZED SERVICE OR REMOVED SERIAL NUMBER The product must not have been previously altered repaired or serviced by anyone other than a service facility authorized by Power Innovations to render such service and the serial number of the product must not have been altered or removed 7 2 1 2 PRODUCT MISUSE OR ABUSE In order to be...

Page 21: ...penses of an on site visit excepting the cost of warrantied parts Service contracts that include the cost of on site visits can be purchased through Power Innovations Customer Service department 7 3 2 Product Shipping If it is determined that the product or a part must be shipped back to the manufacturer for repair the purchaser will assume liability and pay for shipping to Power Innovations or an...

Page 22: ...hen making such an inquiry provide the Service Department with the model number serial number and approximate date of receipt of the equipment 8 2 Returning Equipment If it is deemed necessary to return this equipment to the factory for servicing contact the Service Department for authorization and an RMA number It is often unnecessary to return a failed piece of equipment since this equipment use...