clean and set the dipstick aside. Insert the tube in the dipstick
opening.
5.
Connect the nylon tube to the oil hose (#27) or silicon hose (#34) for
the narrow tube. Push the hose sections into the adapters to ensure
the connection is firm.
6. Swing the support loop (#24) down and step on it to stabilize the fluid
extractor.
7.
Create a vacuum to remove the fluid from the container. The nylon
tube will vibrate and an air gap will appear when the task is complete.
MANUAL PUMP
a.
Pump the handle (#1) until fluid flows into the tube, then the tank
(#8).
b.
You may need to manually pump at several intervals to re-establish
the vacuum.
c.
Press the one-touch controller (#35) together to crimp the line and
prevent the inflow of fluid when the tank is full.
d.
Proceed to empty the tank (see Instructions for Emptying the
Extractor).
e.
Once the hose adapter is reconnected to the tank, pump the
handle to re-establish a vacuum.
f.
Unclamp the one-touch controller to allow the fluid to flow into
the tank again.
g.
Repeat until the fluid tank is empty.
PNEUMATIC
a.
Connect the air hose to the coupler (#56) and start the
compressor.
b.
Open the extractor’s air valve (#45) to create a vacuum. Close the
air valve when fluid begins flowing into the tank (#8). Open the
valve if additional vacuum is needed.
c.
Shut the compressor off and disconnect the air hose once the task
is complete or if the tank must be emptied (see Instructions for