WHEN OPERATING THE GENERATOR

Never start the generator with any load
connected.

Please note: The first 25 hours of operation is considered
the running-in period for the engine.  During this
time operate at less than 75% of the load limit.

Starting the generator:

Step 1: Disconnect any loads.

Fig D.

Step 2: Turn on the fuel cock (tap) clockwise.

Fig E.

Step 3: Turn on the engine switch.

Fig F.

Step 4: Move choke lever to the start (closed  ) position.

The choke may not be needed if the engine
is warm.

Fig G.

12V Battery Charging Facility

The 12V output is designed to charge standard lead
acid batteries (up to 40ah), the overload will cut the
power if a battery that is too big is attempted to be
charged.  Only use the lead provided.
Note: The DC output will not cut out once the battery
is charged and so should not be left unattended for
extended periods.

MAINTENANCE, CARE AND REPAIR

Make sure that the generator is not running when
carrying out maintenance work.

The Power Craft machines have been designed to
operate over a long period of time.  Continuous
satisfactory operation depends upon proper machine
care, regular cleaning and by following the periodic
maintenance schedule. Refer to Fig L on pg 10.  If the
generator is operating in unusually dust or hot conditions
the time between servicing the generator must be
decreased.
Inspect the generator and extension cables periodically
and if damaged, have them repaired by a qualified
person or authorised service body.  Do not use the
generator with damaged parts.

Refer to the generator schematic diagrams on pg 11
for details of component locations.

Oil replacement.

Warm up engine on level ground.

Remove filler cap.

Open drain plug and let oil drain completely into
a pan placed under the engine.

Check gaskets, replace if required. Refit drain plug
and refill engine with clean oil.

Replace filler cap.

Spark plug inspection.

Remove spark plug with the plug spanner supplied.

Inspect the spark plug. It should be a tan colour.

Adjust the gap: 0.7 – 0.8mm (0.028 – 0.031in).

Replace the spark plug with correct torque: 28Nm
(2.8m.kg; 20ft lb).

Replace spark plug if required. (NGK) BR5ES

Exhaust Screen inspection.

Wait for exhaust to cool.

Exhaust screen may be blocked with carbon
deposits.

Remove the screen by unscrewing the two 10mm
bolts at exhaust inlet and one 10mm bolt on
alternator.  Remove exhaust muffler.

Clean the screen with a wire brush and refit.
Replace exhaust screen if damaged.

Step 5: Pull slowly on the starter cord until it engages.

Then pull sharply to start the engine.

Fig H.

Step 6: If starting from cold allow the engine to run

with no load for a few minutes to allow the
engine to warm up.

Step 7: Move the choke lever to the open position.

Fig I.

Step 8: Plug in the appliance power cord

Stopping the generator:

Step 1: Unplug all a ppliance po wer cords.
Step 2: Turn the engine switch to off.
Step 3: Turn the fuel cock (tap) to the off position.

IMMEDIATELY SWITCH OFF THE GENERATOR
IN CASE OF:

Excessive engine noise – knocking or rattling.

Broken switches.

Smoke or smell caused by scorched insulation
other than that through the exhaust.

Operation load and ratings:

Please ensure that the load on the generator falls within
its capacity as specified in the table before plugging
in any power cords.

Ensure also that the cord and plug capacity is sufficient
for the duty.

Fig J.

50Hz
220V/230V
AC

Lighting

Power
factor

1

0.8-0.95

0.4-0.75
(@85%eff)

Maximum
loading of
connected
appliances
Power Craft 720

Up to 650W

Up to
520W

Less than
220W

Power
Tools

Induction
Motors

Air filter cleaning

Caution!

 Do not run the engine without the

air filter element in place.

Unscrew the air filter cover.

Remove filter element and wash well in solvent.

Pour a small amount of oil (SAE 20) onto the filter
element and gently squeeze out any excess oil.

Replace the filter element and air filter cover.

Be sure the filter cover seals properly all around.

Helpline: UK  08707 323023

ROI  1800 481 005

Helpline: UK  08707 323023

ROI  1800 481 005

Summary of Contents for PC720LR

Page 1: ...curred due to defective materials or workmanship repairs will be carried out free of charge This guarantee does not apply to normal wear and tear nor does it cover any damage caused by misuse careless or unsafe handling alterations accident or repairs attempted or made by any persons other than the authorised Power Craft warranty repair agent Your Power Craft guarantee is not effective unless you ...

Page 2: ... Litres 7 5 Max Max fill recommended 6 5 Ltrs Spark Plug Type BPR5ES NGK Gap 0 7 0 8mm Sound Pressure Level LwA 85 LwA 92 Max Sound Power Level Outdoor Noise 7m 62dB A Dimensions L W H mm 375 x 315 x 370 Excluding carry handle Weight kg 21 7 11 IMPORTANT NOTICE Please note that this generator is fitted with a 2 stroke petrol engine and must only be operated with mixed unleaded petrol 2 stroke oil ...

Page 3: ...uards or covers removed Exhaust fumes can kill Exhaust fumes are highly poisonous Always operate the generator outdoors with good ventilation Provide good ventilation for the generator Do not cover the generator with a cloth or plastic sheet and it should be at least 3 feet 1m away from buildings The generator requires a free air flow around the unit for ventilation and air supply Lift the generat...

Page 4: ...ontact your appliance manufacturer ENVIRONMENTAL PROTECTION Periodically inspect the exhaust to ensure that it has not corroded Ensure the generator is switched off and cold first A leaking exhaust muffler will cause an increase in noise levels Do not dispose of fuel oil into the sewer system Take to your local community facilities for oil disposal TROUBLESHOOTING GUIDE Symptom Possible cause Corr...

Page 5: ...filling we recommend that the fuel tank only be filled with 6 5 litres of fuel Add correct quantity of 2 stroke oil Always add oil to petrol never petrol to oil Always screw down fuel cap Once the petrol and oil are in the fuel tank shake well to mix Clean up any spilled fuel immediately Move generator at least 12 feet 4m away from the fuelling area before starting Fuel cock To remove the fuel coc...

Page 6: ...park plug with the plug spanner supplied Inspect the spark plug It should be a tan colour Adjust the gap 0 7 0 8mm 0 028 0 031in Replace the spark plug with correct torque 28Nm 2 8m kg 20ft lb Replace spark plug if required NGK BR5ES Exhaust Screen inspection Wait for exhaust to cool Exhaust screen may be blocked with carbon deposits Remove the screen by unscrewing the two 10mm bolts at exhaust in...

Reviews: